| 数据搜索系统,热门电子元器件搜索 |
|
UB242CG-AG6-R 数据表(PDF) 6 Page - Unisonic Technologies |
|
|
|||||||||||||||||||||||||||||
UB242CG-AG6-R 数据表(HTML) 6 Page - Unisonic Technologies |
|
6 / 13 page ![]() UB242 Preliminary CMOS IC UNISONICTECHNOLOGIESCO.,LTD 6 of 13 www.unisonic.com.tw QW-R502-307.e DESCRIPTION OF OPERATION 1. Normal Condition The voltage of the battery connected between VDD and VSS can be monitored by the UB242.The voltage difference between CSI and VSS can sense the charge and discharge scheme. Under this condition: VODL<VDD<VOCU and VCH<VCSI<VOI1, UB242 will turn on the M2 (charging) and M1 (discharging) control MOSFETs. 2. Overcharge Condition M2 will be turned off under this condition: the battery voltage becomes higher than the overcharge detection voltage (VOCU) during normal charging condition through a delay time longer than TOC (the overcharge detection delay time). 3. Release of Overcharge Condition Two ways to return to normal condition from overcharge condition: (1.) Under the condition: the battery is self discharging, and if VDD<VOCR and VOI1>VCSI>VCH occurs, UB242 will be back to normal condition. (2.) Connect UB242 to a load and remove the charger. 4. Overdischarge Condition M1 will be turned off to stop discharging when the battery voltage falls below the overdischarge detection voltage (VODL) during discharging condition and through a delay time longer than TOD (the overdischarge detection delay time).And then CSI will be pulled up to VDD through an internal resistance.When VCSI>VOI2,the chip will enter into power-down mode. In this mode, the current consumption is lower than 0.1μA. 5. Release of Power-down mode There are two ways back to normal condition: (1.) If VCSI<VCH (Charger detection), when VDD>VODL (2.) If VCH<VCSI<VOI2, the condition VDD>VODR 6. Charger Detection Charger detection is this action: while connecting to a charger after entering into power-down mode, then if VDD<VCH, M1 will be turned on when VDD>VODL, and then the system will be back to normal condition as described in 1) of previous section. 7. Abnormal Charge Current Condition The abnormal charge current condition is when a charger is connected to the battery system in normal condition, then if VDD<VOCU and VCSI<VCH occurs through a delay time than TOC (delay time of overcharge detection), and in this condition M2 will be turned off to stop this charging status. 8. Over Current/Short Circuit Condition The over current (or short circuit) condition is when the current is too large during discharging under normal condition as a result of the voltage detected by CSI is greater than VOI1 (or VOI2) through a delay time TOI1 (TOI2).In this over current (or short circuit) condition: M1 will be turned off and CSI will be pulled down to VSS through an internal resistance. 9. Release of Over Current/Short Circuit Condition If the load is removed or the impedance between VBAT+ and VBAT- is larger than 500kΩ as well as VCSI<VOI1, M1 will be turned on and the back to normal condition. 10. DS Pin The delay time of the overcharge and overdischarge can be reduced to within 50ms by forcing DS to VDD. A 1.6MΩ pull down resistor should be connected between DS pin and VSS internally. In the actual application DS pin should be left open or connected to VSS. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |