| 数据搜索系统,热门电子元器件搜索 |
|
EM5301F 数据表(PDF) 9 Page - Excelliance MOS Corp. |
|
|
|||||||||||||||||||||||||||||
EM5301F 数据表(HTML) 9 Page - Excelliance MOS Corp. |
|
9 / 12 page ![]() 2013/5/2 Rev.A.1 9 EM5301F/G Functional Description EM5301F/G is a voltage mode synchronous buck PWM controller. This device provides complete protection function such as over current protection, under voltage protection and over voltage protection. Supply Voltage The VCC pin provides the bias supply of EM5301F/G control circuit, as well as lower MOSFET’s gate and the BOOT voltage for the upper MOSFET’s gate. A minimum 0.1uF ceramic capacitor is recommended to bypass the supply voltage. Power ON Reset To let EM5301F/G start to operation, VCC voltage must be higher than its POR voltage even when REFIN voltage is pulled higher than enable high voltage. Typical POR voltage is 8.8V. Shutdown The COMP/SD pin can be used to enable or disable EM5301F/G. Pull down COMP/SD pin below 0.2V can disable the controller. Soft Start EM5301F/G provides soft start function internally. The FB voltage will track the internal soft start signal, which ramps up from zero during soft start period. OCP, Over Current Protection The over current function protects the converter from a shorted output by using lower MOSFET’s on-resistance to monitor the current. The OCP level can be calculated as the following equation: DS(ON) OCP OCP R V I − = When OCP is triggered, EM5301F/G will shut down the converter and cycles the soft start function in a hiccup mode. If over current condition still exist after 3 times of hiccup, EM5301F/G will shut down the controller and latch. UVP, Under Voltage Protection The FB voltage is monitored for under voltage protection. The UVP threshold is typical 0.6V. When UVP is triggered, EM5301F/G will shut down the converter and cycles the soft start function in a hiccup mode. OVP, Over Voltage Protection The FB voltage is monitored for over voltage protection. The OVP threshold is typical 1.04V. When OVP is triggered, EM5301F/G will turn off upper MOSFET and turn on lower MOSFET. Feedback Compensation Fig.1 shows the voltage mode control loop for a synchronous-rectified buck converter. The compensation network consists of the error amplifier and the impedance networks ZIN and ZFB. The goal of the compensation network is to provide a closed loop transfer function with adequate phase margin. OSC Lo VOUT Co ESR VIN PHASE DRIVER PWM COMPARATOR VOSC ZI ZFB REFERENCE ERROR AMP DRIVER VOUT ZIN ZFB REFERENCE FB COMP C1 R2 C2 C3 R3 R1 Fig.1 Compensation for Voltage Mode Buck Converter |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |