| 数据搜索系统,热门电子元器件搜索 |
|
D10IPFPQ 数据表(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
D10IPFPQ 数据表(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 16 page ![]() Push Button Remote 0.04 sec. ≤ T ≤ 0.8 sec. Result Single-click both buttons simultaneously. Triple-pulse the remote line.* T T T T T Pointer icon: moves to the other channel indicator. * Note: Triple-pulse will change the display, but will not save. To save Channel Select, make an adjustment to that channel as a TEACH, SET, or Sensor Setup. Two-Point Static TEACH (Threshold) • Establishes a single switching threshold • Threshold position is adjustable using “+” and “-” buttons (see Manual Adjust on page 9) Static TEACH is the traditional setup method, used when two conditions can be presented by the user. The sensor locates a single sensing threshold (the switchpoint) midway between the two taught conditions, with the Output ON condition on one side, and the Output OFF condition on the other. The first condition taught is the ON condition. The Output ON and OFF conditions can be reversed by changing Light/Dark Operate status in Setup mode (see Sensor Setup on page 10 ). Sensor positions threshold midway between taught conditions Darkest (no signal) Most Light (saturated signal) Output OFF Output ON 2nd Taught Condition 1st Taught Condition Position adjusted by Manual Adjust Figure 4. Static TEACH (Light Operate shown) Static TEACH and Manual Adjust. Discrete output: Using Manual Adjust with Static TEACH moves the switching threshold. Analog output: Using Manual Adjust with Static TEACH moves the entire span up (+) or down (-). Contrast Values 500+ Excellent: Very stable operation. 100-500 Good: Minor sensing variables will not affect sensing reliability. 32-99 Low: Minor sensing variables may affect sensing reliability. 0-31 Marginal: Consider an alternate sensing scheme. Figure 5. Contrast Values 1. Access the Static TEACH Mode. Method Action Result Push Button Press and hold the Static (-) button > 2 seconds. • Display flashes “1St” • Arrow icon turns red Remote Input2 No action is required; the sensor is automatically ready for the 1st TEACH condition 2. TEACH the Output ON condition. 2 0.04 seconds ≤ T ≤ 0.8 seconds D10 Expert™ - Analog and Discrete Outputs 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 65448 Rev. G |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |