7 / 16 page ![]() 2. SET the sensing condition. Method Action Result Push Button a. Present the sensing condition b. Double-click the Static button TEACH conditions accepted • Display flashes “Sn6l,” then "Pt" twice • Sensor returns to RUN mode with new settings • Arrow icon turns green TEACH conditions unacceptable • Display flashes “FAIL” and returns to “1St” • Arrow icon remains red • After 60 seconds, the sensor returns to RUN mode (Arrow icon turns green) without changing settings Remote Input Double-pulse the remote line T T T Single-Point Light Set - Discrete Only • Sets a threshold slightly below the taught condition. • Any condition darker than the threshold condition causes the output to change state • Threshold position is adjustable using the “+” and “-” buttons (see Manual Adjust on page 9) • Recommended for applications where only one condition is known, for example a stable light background with varying darker targets A single sensing condition is presented, and the sensor positions a threshold slightly below the presented condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the Light/ Dark Operate setting (see Sensor Setup on page 10). Threshold position adjusted by Manual Adjust Sensor positions threshold slightly below the presented condition Darkest (no signal) Most Light (saturated signal) Output OFF Output ON Condition Presented Figure 9. Single-Point Light Set (Light Operate shown) Light SET and Light/Dark Operate Selection Light Set teaches the Output OFF condition and forces the sensor into Dark Operate (DO) mode. The sensor can be reconfigured to Light Operate (LO) mode after the condition has been taught (see Sensor Setup on page 10). Mode Threshold Offset (counts below taught signal value) Super High-Speed 30 High-Speed 22 High-Power 9 Super High-Power 6 Figure 10. Light Set Threshold Offset 1. Access the SET Mode. D10 Expert™ - Analog and Discrete Outputs P/N 65448 Rev. G www.bannerengineering.com - Tel: +1-763-544-3164 7 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |