| 数据搜索系统,热门电子元器件搜索 |
|
S-8211CDD-M5T1U 数据表(PDF) 24 Page - ABLIC Inc. |
|
|
|||||||||||||||||||||||||||||
S-8211CDD-M5T1U 数据表(HTML) 24 Page - ABLIC Inc. |
|
24 / 43 page ![]() BATTERY PROTECTION IC FOR 1-CELL PACK S-8211C Series Rev.7.7_03 24 8. Delay circuit The detection delay times are determined by dividing a clock of approximately 3.5 kHz by the counter. Remark 1. The discharge overcurrent detection delay time (tDIOV) and the load short-circuiting detection delay time (tSHORT) start when the discharge overcurrent detection voltage (VDIOV) is detected. When the load short- circuiting detection voltage (VSHORT) is detected over the load short-circuiting detection delay time (tSHORT) after the detection of discharge overcurrent detection voltage (VDIOV), the S-8211C Series turns the discharging control FET off within the load short-circuiting detection delay time (tSHORT) from the time of detecting VSHORT. DO Pin VM Pin VDD VDD Time VDIOV VSS VSS VSHORT Load short-circuiting detection delay time (tSHORT) Time tD 0 tD tSHORT Figure 10 2. With power-down function When any overcurrent is detected and the overcurrent continues for longer than the overdischarge detection delay time (tDL) without the load being released, the status changes to the power-down status at the point where the battery voltage falls below overdischarge detection voltage (VDL). When the battery voltage falls below overdischarge detection voltage (VDL) due to overcurrent, the S-8211C Series turns the discharging control FET off via overcurrent detection. In this case, if the recovery of the battery voltage is so slow that the battery voltage after the overdischarge detection delay time (tDL) is still lower than the overdischarge detection voltage (VDL), the S-8211C Series shifts to the power-down status. Without power-down function When any overcurrent is detected and the overcurrent continues for longer than the overdischarge detection delay time (tDL) without the load being released, the status changes to the overdischarge status at the point where the battery voltage falls below overdischarge detection voltage (VDL). When the battery voltage falls below overdischarge detection voltage (VDL) due to overcurrent, the S-8211C Series turns the discharging control FET off via overcurrent detection. In this case, if the recovery of the battery voltage is so slow that the battery voltage after the overdischarge detection delay time (tDL) is still lower than the overdischarge detection voltage (VDL), the S-8211C Series shifts to the overdischarge status. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |