数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

A6801SEP 数据表(PDF) 4 Page - Allegro MicroSystems

部件名 A6801SEP
功能描述  DABiC-5 Latched Sink Drivers
PDF  12 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  ALLEGRO [Allegro MicroSystems]
网页  http://www.allegromicro.com
标志 ALLEGRO - Allegro MicroSystems

A6801SEP 数据表(HTML) 4 Page - Allegro MicroSystems

  A6801SEP Datasheet HTML 1Page - Allegro MicroSystems A6801SEP Datasheet HTML 2Page - Allegro MicroSystems A6801SEP Datasheet HTML 3Page - Allegro MicroSystems A6801SEP Datasheet HTML 4Page - Allegro MicroSystems A6801SEP Datasheet HTML 5Page - Allegro MicroSystems A6801SEP Datasheet HTML 6Page - Allegro MicroSystems A6801SEP Datasheet HTML 7Page - Allegro MicroSystems A6801SEP Datasheet HTML 8Page - Allegro MicroSystems A6801SEP Datasheet HTML 9Page - Allegro MicroSystems Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 12 page
background image
4
Worcester, Massachusetts 01615-0036 (508) 853-5000
115 Northeast Cutoff, Box 15036
www.allegromicro.com
A6800/A6801
DABiC-5 Latched Sink Drivers
Timing Requirements and Specifications
(Logic Levels are VDD and Ground)
NOTE: Information present at an input is transferred
to its latch when the STROBE is high. A high CLEAR
input will set all latches to the output off condition
regardless of the data or STROBE input levels. A high
Key
Description
Time (ns)
A
Minimum data active time before Strobe enabled (Data Set-Up Time)
25
B
Minimum data active time after Strobe disabled (Data Hold Time)
25
C
Minimum Strobe pulse width
50
D
Maximum time between Strobe activation and transition from output on to output off*
500
E
Minimum time between Strobe activation and transition from output off to output on*
500
F
Maximum time between Output Enable activation and transition from output on to output off*
500
G
Minimum time between Output Enable activation and transition from output off to output on*
500
H
Minimum Clear pulse width
50
I
Minimum data pulse width
100
CLEAR
STROBE
OUTPUT
ENABLE
INN
OUTN
A
C
BC
B
G
D
E
H
A
C
B
I
E
G
F
*Conditions for output transition testing are: VDD = 50 V, VCC = 5 V, R1 = 500 Ω, C1 ≤ 30 pF.
OUTPUT ENABLE will set all outputs to the off con-
tdition, regardless of any other input conditions. When
the OUTPUT ENABLE is low, the outputs depend on
the state of their respective latches.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com