| 数据搜索系统,热门电子元器件搜索 |
|
AS8846 数据表(PDF) 13 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8846 数据表(HTML) 13 Page - ams AG |
|
13 / 35 page ![]() Data Sheet AS8446 Revision 1.8, Date 2005-03-17 Page 13 of 35 Programming of the motor current measurement unit and the over current detection unit The motor current measurement unit operates with an external current measurement resistor Rmeas in the high side motor line. The chip has two measurement amplification channels with separately programmable amplification factors: a) normal motor current measurement, channel 1 AVmeas_norm = VA_current / Vmeas with Vmeas = (VCMP - VCMN), analog output A_current (multiplexed to output ADC) and b) over current measurement with extended measurement range, channel 2 AVmeas_overc = VA_overc / Vmeas, analog output A_overc (multiplexed to output ADC). In general all programming possibilities in table 14 can be used to build up a measurement system in the defined limits. The programming words are sent from the µP via the Three-Wire Interface to the AS8446 during start up of the system. The typical value of Vmeas_nom = (VCMP - VCMN)nom is 50 mV, corresponding to 100% of the motor current. In the whole system the analog outputs A_current or A_overc are used by the ADC of the µP to regulate and control the system. There is only one exception: The over current detection and protection is realized directly by the over current measurement channel in order to act very fast in case of an over current situation e.g. short circuit of the motor. Figure 8 Programming examples of the current Figure 9 Programming examples of the over current measurement channels detection Figure 8 shows the programming of the normal current measurement channel (red lines, output voltage VCUR) and the over current measurement channel with extended measurement range (blue lines, output voltage VCOVER). The three lines with the parameters AV_TRIMM = 70, 80, 90 indicate the trimming range of the external measurement resistor (+ 12.5 % in steps of 1.25 %). The total range of the normal measurement amplification is AVmeas_norm = 70 to 360 corresponding to input voltages Vmeas_max = 11 mV to 57 mV. The total range of the over current measurement amplification is AVmeas_overc = 17.5 to 90 corresponding to input voltages Vmeas_max = 44 mV to 229 mV. Figure 9 shows an example of the programming of the over current threshold level (generation of the over current signal VPOV, red lines): AVmeas_overc = 20 and OVERC_level = 0.5 V to 4.0 V in steps of 0.5 V. All programming possibilities are given in table 14 below. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |