4 / 9 page ![]() E8Y E8Y 5 s FUNCTIONS Operation Function Description Pressure units Switches between mmH2O and kPa, excluding the E8Y- -F flow sensor. switching Comparitive ON/ Two independent outputs can be set. OFF output (two (1) Output mode (mode is automatically determined from the ON and OFF point set values.) independent Hysteresis mode: outputs If ON point point set value > OFF point set value For normal open: For normal close: Window mode: If ON point set value < OFF point set value For normal open: For normal close: (2) Setting mode ON point / OFF point: Each output can be set in the range from 0 to the rated value. Set value: 0 to rated value Output configuration: Each output can be set as normally open (NO) or normally closed (NC). Setting: NO <> NC Hysteresis: Each output can be set at 10% of the range from 0 to the rated value. (Effective in window mode and 2-point auto-teaching mode.) Setting range: (0 to rated value) x 10% Auto-teaching When the auto-teaching mode is used, measured values can be input as ON point or OFF point set values instead of key inputs. Two types of auto-teaching are available: 1-point auto-teaching, where only one single point is set, and 2-point auto-teaching, where two points are set. (1) 2-point auto-teaching (Hysteresis mode teaching) This function automatically sets the ON point and OFF point for the comparative output by designating a point with no object (TEACH 1) and a point with an object (TEACH 2) using actual objects. The outputs are made in hysteresis mode. The hysteresis is a set value. The set value is the mid-point between TEACH 1 and TEACH 2. Example: If TEACH 1 is 0.25 kPa and TEACH 2 is 0.95 kPa, the ON point set value = (0.95+0.25)/2 = 0.60 (This table continues on the next page) 0 Output ON OFF OFF set value ON set value Pressure value 0 Output ON OFF OFF set value ON set value Pressure value Hysteresis width (set value) Output ON OFF OFF set value ON set value Pressure value Hysteresis width (set value) Output ON OFF OFF set value ON set value Pressure value Hysteresis width (set value) Hysteresis width (set value) 0 Output ON OFF OFF point Pressure value ON point Hysteresis width Set value TEACH 1 TEACH 2 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |