| 数据搜索系统,热门电子元器件搜索 |
|
E8Y-A2Y-R 数据表(PDF) 5 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E8Y-A2Y-R 数据表(HTML) 5 Page - Omron Electronics LLC |
|
5 / 9 page ![]() E8Y E8Y 6 Functions Table - continued from previous page Function Description Auto-teaching (2) 1-point auto-teaching (Window mode teaching) (continued) This function automatically sets the ON point and OFF point for the comparitive output by inputing a reference point (TEACH 1) using an actual object. The function operates only when an object exists. The outputs are made in the window mode. The hysteresis width and window width are set values. (The window width set value is valid only when 1-point teaching is set. Setting range: (0 to rated value) x 30%) The ON point and OFF point set values are set at the reference point ±window width. Example: If the reference point (TEACH 1) is 0.90 kPa and the window width is 0.50 kPa, the ON set value = (0.90 - 0.50)/2 = 0.20 and the OFF point set value = (0.90+0.50)/2 = 0.70. Key-protect This function restricts switch operation to prevent the set value from being easily changed. (Set value lock Set value: OFF <> ON function) Set value Hold down the ADJ key for several seconds in the measurement mode to activate this function. zero-setting Speed control Select from three values of display speed for the measured pressure values. Set value: 0.1 s, 0.5 s, 1.0 s function with measured pressure display Error display (1) Pressure warning during zeroing: Error display and warning if excess pressure or flow (exceeding rated value ±5%) is applied during zeroing. (2) Teaching error display: Warning if teaching is unsuccessful. (3) Short-circuit protection and display: If overcurrent flows in a connected load, the abnormal status is notified by an error display and the OUT LED, for the corresponding output, flashing. Transistor acts to cut the abnormal current. (4) Abnormal pressure or flow detection: The diplayed value flashes to indicate the abnormal status if the applied pressure or flow exceeds the rated value by 10%. This error is automatically reset when the supplied value enters the rated range. (5) ON/OFF point input error warning: Indicates if the difference between the ON point and OFF point in the window mode exceeds the hysteresis value + setting resolution (0.01 kPa/1 mmH2O). 0 Output ON OFF OFF point Pressure value ON point Hysteresis width (TEACH 1) Hysteresis width Window width Standard value Window width |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |