164 / 167 page ![]() ST7LITE3 164/167 IMPORTANT NOTES (Cont’d) break. This can be ensured by temporarily disa- bling interrupts. The exact sequence is: - Disable interrupts - Reset and Set TE (IDLE request) - Set and Reset SBK (Break Request) - Re-enable interrupts LIN mode If the LINE bit in the SCICR3 is set and the M bit in the SCICR1 register is reset, the LINSCI is in LIN master mode. A single break character is sent by setting and resetting the SBK bit in the SCICR2 register. In some cases, the break character may have a longer duration than expected: - 24 bits instead of 13 bits Occurrence The occurrence of the problem is random and pro- portional to the baudrate. With a transmit frequen- cy of 19200 baud (fCPU=8MHz and SCI- BRR=0xC9), the wrong break duration occurrence is around 1%. Analysis The LIN protocol specifies a minimum of 13 bits for the break duration, but there is no maximum value. Nevertheless, the maximum length of the header is specified as (14+10+10+1)x1.4=49 bits. This is composed of: - the synch break field (14 bits), - the synch field (10 bits), - the identifier field (10 bits). Every LIN frame starts with a break character. Adding an idle character increases the length of each header by 10 bits. When the problem occurs, the header length is increased by 11 bits and be- comes ((14+11)+10+10+1)=45 bits. To conclude, the problem is not always critical for LIN communication if the software keeps the time between the sync field and the ID smaller than 4 bits, i.e. 208us at 19200 baud. The workaround is the same as for SCI mode but considering the low probability of occurrence (1%), it may be better to keep the break generation se- quence as it is. 16.2.2 Header Time-out does not prevent wake- up from mute Mode Normally, when LINSCI is configured in LIN slave mode, if a header time-out occurs during a LIN header reception (i.e. header length > 57 bits), the LIN Header Error bit (LHE) is set, an interrupt oc- curs to inform the application but the LINSCI should stay in mute mode, waiting for the next header reception. Problem Description The LINSCI sampling period is Tbit / 16. If a LIN Header time-out occurs between the 9th and the 15th sample of the Identifier Field Stop Bit (refer to Figure 107), the LINSCI wakes up from mute mode. Nevertheless, LHE is set and LIN Header Detection Flag (LHDF) is kept cleared. In addition, if LHE is reset by software before this 15th sample (by accessing the SCISR register and reading the SCIDR register in the LINSCI interrupt routine), the LINSCI will generate another LINSCI interrupt (due to the RDRF flag setting). Figure 107. Header Reception Event Sequence LIN Synch LIN Synch Identifier Field Field Break THEADER Active mode is set RDRF flag is set Critical Window ID field STOP bit (RWU is cleared) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |