| 数据搜索系统,热门电子元器件搜索 |
|
ZSC31015EIG1-R 数据表(PDF) 29 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZSC31015EIG1-R 数据表(HTML) 29 Page - Renesas Technology Corp |
|
29 / 53 page ![]() © 2016 Integrated Device Technology, Inc 29 November 14, 2016 ZSC31015 Datasheet Table 3.3 Total Transmission Time for Different Update Rate Settings and Output Configuration Update Rate Baud Rate* Idle Time Transmission Time – Bridge Only Readings Transmission Time – Bridge & Temperature Readings 1 ms (1 kHz) 32 kHz 1.0 ms 20.5 bits 31.30 µs 1.64 ms 31.0 bits 31.30 µs 1.97 ms 5 ms (200 Hz) 32 kHz 4.85 ms 20.5 bits 31.30 µs 5.49 ms 31.0 bits 31.30 µs 5.82 ms 25 ms (40 Hz) 8 kHz 22.5 ms 20.5 bits 125.00 µs 25.06 ms 31.0 bits 125.00 µs 26.38 ms 125 ms (8 Hz) 8 kHz 118.0 ms 20.5 bits 125.00 µs 120.56 ms 31.0 bits 125.00 µs 121.88 ms * Typical values. Minimum baud rate for 1 ms or 5 ms: 26kHz; maximum baud rate for 25 ms or 125 ms: 9.6kHz. The temperature raw reading is performed less often than a bridge reading because the temperature changes more slowly. The 3 rd column in Table 3.2 shows the timing for the special measurements (temperature and bridge measurement) in the different update rate modes. For lower update rates, the output is followed by a power-down as shown in Figure 3.9. Figure 3.9 ZACwire™ Output Timing for Lower Update Rates It is easy to program any standard microcontroller to communicate with the ZSC31015. IDT can provide sample code for a MicroChip PIC microcontroller. 3.2.5. High Level Protocol The ZSC31015 will listen for a command/data pair to be transmitted for the 3 ms after the de-assertion of its internal Power On Reset (POR). If a transmission is not received within this time frame, then it will transition to Normal Operation Mode (NOM). In the NOM, it will output bridge data in 0-1V analog, rail-to-rail ratiometric analog, or digital depending on how the part is currently configured. If the ZSC31015 receives a Start_CM command within the first 3 ms after the de-assertion of POR, then it will go into Command Mode (CM). In this mode, calibration/configuration commands will be executed. The ZSC31015 will acknowledge successful execution of commands by transmission of A5HEX. The calibrating /configuring master will know a command was not successfully executed if no response is received after 130ms of issuing the command. Once in command interpreting/executing mode, the ZSC31015 will stay in this mode until power is removed or a Start NOM (Start Normal Operation Mode) command is received. The Start_CM command is used as an interlock mechanism to prevent a spurious entry into Command Mode on power up. The first command received within the 3ms window of POR must be a Start_CM command to enter into command interpreting mode. Any other commands will be ignored. ZACwireTM Output Calculation 160 s Settling Time 64 s Power-On Settling 128 s Power Down (determined by Update Rate) ADC Conversion 768 s Calculation 160 s ZACwireTM Output |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |