7 / 10 page ![]() MODEL: M1EAXV-2 M1EAXV-2 SPECIFICATIONS ES-5995 Rev.2 Page 7/10 https://www.m-system.co.jp/ MODE ITEM SETTING PARAMETER RANGE UNIT INITIAL VALUE Ch2 setting 111 Ch2 Input range 0 – 50 mA -1000 – +1000 mV -10 – +10 V — 0 – 50 mA 112 Ch2 0 % input setting 0.00 – 48.00 -1000.0 – 900.0 -10.000 – 9.000 mA mV V 4.00 113 Ch2 100 % input setting 2.00 – 50.00 -900.0 – 1000.0 -9.000 – 10.000 mA mV V 20.00 114 Ch2 0 % input scaling -99999 – 999999 — 0.00 115 Ch2 100 % input scaling -99999 – 999999 — 100.00 116 Ch2 Input decimal point No decimal point The number of decimal places : 1 – 5 — 2 places of decimals 117 Ch2 Unit (INP Scaling) Choose from 68 types * — % 130 Ch2 L1 alarm enable Disable / Enable — Enable 131 Ch2 L1 alarm setpoint -99999 – 999999 * — 20.00 132 Ch2 L1 trip action High / Low — Low 133 Ch2 L1 deadband 0 – 999999* — 0.01 134 Ch2 L1 coil at alarm Energized / De-energized — Energized 140 Ch2 L2 alarm enable Disable / Enable — Enable 141 Ch2 L2 alarm setpoint -99999 – 999999 * — 80.00 (2 points alarm) 30.00 (4 points alarm) 142 Ch2 L2 trip action High / Low — High (2 points alarm) Low (4 points alarm) 143 Ch2 L2 deadband 0 – 999999 * — 0.01 144 Ch2 L2 coil at alarm Energized / De-energized — Energized 150 Ch2 L3 alarm enable Disable / Enable — Enable 151 Ch2 L3 alarm setpoint -99999 – 999999* — 70.00 152 Ch2 L3 trip action High / Low — High 153 Ch1 L3 deadband 0 – 999999* — 0.01 154 Ch2 L3 coil at alarm Energized / De-energized — Energized 160 Ch2 L4 alarm enable Disable / Enable — Enable 161 Ch2 L4 alarm setpoint -99999 – 999999 * — 80.00 162 Ch2 L4 trip action High / Low — High 163 Ch2 L4 deadband 0 – 999999 * — 0.01 164 Ch2 L4 coil at alarm Energized / De-energized — Energized 170 Ch2 Alarm ON-delay time 0 – 999 sec. 0 171 Ch2 Power ON-delay time 0 – 999 sec. 5 172 Ch2 Latching alarm Disable / Enable — Disable 179 Ch2 Filter time constant 0 – 30 sec. 0 180 Ch2 Input Zero ne adjust -5.000 – 5.000 % 0.000 181 Ch2 Input Span ne adjust 95.000 – 105.000 % 100.000 189 Ch2 Alarm test — — Cancel 01 Lockout setting Lock / Unlock — Lock Advanced 201 Display setting Upper: choose from 14 types* Lower: choose from 15 types* — Upper: Ch1 ALARM (Scaling) Lower: Ch2 ALARM (Scaling) 202 Channel enable Choose from 3 types — Ch1 enable Ch2 enable 203 Brightness 1 (darkest) — 4 (brightest) — 4 204 Display timeout 0 (always on), 1 — 60 min 10 205 Reset all settings OFF / RESET — OFF 206 Version indication — — — 01 Lockout setting Lock / Unlock — Lock * For details, refer to the operating manual (EM-5995-B). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |