| 数据搜索系统,热门电子元器件搜索 |
|
225EDLC-R 数据表(PDF) 4 Page - Vishay Siliconix |
|
|
|||||||||||||||||||||||||||||
225EDLC-R 数据表(HTML) 4 Page - Vishay Siliconix |
|
4 / 6 page ![]() 225 EDLC-R ENYCAP™ www.vishay.com Vishay BCcomponents Revision: 02-Jul-2021 4 Document Number: 28449 For technical questions, contact: energystorage@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Table 4 Notes • General remark: temperatures to be measured at capacitor case (1) Conditions: electrical measurements at 20 °C, unless otherwise specified (2) Rated capacitance CR and ESRDC RUGGEDIZED FOR HIGH HUMIDITY - BIASED HUMIDITY TESTING PARAMETER PROCEDURE (AT RATED VOLTAGE) REQUIREMENTS Humidity (relative) 85 % After loading the capacitor for the specified time at maximum category temperature Tmax. = 85 °C and 85 % relative humidity, and derated permissible maximum operating voltage U = 2.3 V, following parameters are valid within a timeframe of 1000 h: No visible damage No leakage of electrolyte ΔC/C: within ± 30 % of minimum initial specified value ESR: less than 3 x initial specified value Leakage: less than initial specified value Temperature 85 °C TEST PROCEDURES AND REQUIREMENTS (1) NAME OF TEST PROCEDURE (quick reference) Capacitance CR and ESRDC Measured by DC discharging method as described in “Measuring of Characteristics”. (2) Maximum peak current Non-repetitive current for maximum 1 s at specified operating temperature. Maximum operating voltage (refer to derating table) must not be exceeded. Usually to be tested with constant current discharge from UR to 0.5 x UR. Maximum current should not be used in normal operation and is only provided as reference value. Leakage current IL Measured at UR. Capacitor is charged to the rated voltage at 20 °C. Leakage current is the current at specified time that is required to keep the capacitor charged at the rated voltage. Endurance After loading the capacitor for specified time at maximum category temperature Tmax. = 85 °C and derated permissible maximum operating voltage U = 2.3 V, following parameters are valid within a timeframe of 1000 h: Capacitance Within ± 30 % of minimum initial specified value ESR Less than 3 x initial specified value Leakage Within specified value Useful life After loading the capacitor for specified time at maximum category temperature Tmax. = 85 °C and derated permissible maximum operating voltage U = 2.3 V, following parameters are valid within a timeframe of 2000 h: Capacitance Within ± 50 % of minimum initial specified value ESR Less than 4 x initial specified value Leakage Within specified value Storage at upper category temperature After loading the capacitor of specified time at maximum category temperature Tmax. = 85 °C and without charge and under 40 % RH, following parameters are valid within a timeframe of 1000 h: Capacitance Within ± 30 % of minimum initial specified value ESR Less than 3 x initial specified value Leakage Within specified value Shelf life Stored uncharged at 20 °C. Parameter within initial specification Cycle life Cycles at 20 °C between rated voltage and half of rated voltage UR with constant current and 1 s rest between charge and discharge: > 500 000 cycles Capacitance Within ± 30 % of minimum initial specified value ESR Less than 3 x initial specified value Stored energy E, specific energy Ed and Ev E [Wh] = ½ x C x (UR)2 x 1/3600 Ed [Wh/kg] = ½ x C x (UR)2 x 1/3600 x 1/mass Ev [Wh/L] = ½ x C x (UR)2 x 1/3600 x 1/volume Soldering Hand or wave soldering allowed. For details refer to soldering requirements for radial aluminum electrolytic capacitors in supplementary document. Cleaning For printed circuit board cleaning apply non-aggressive cleaning agents only. For details refer to cleaning requirements for aluminum electrolytic capacitors in supplementary document. Environmental conditions Do not expose capacitors to • temperatures outside specified range • high humidity atmospheres; except series 225 which is ruggedized for high humidity 85 °C and 85 % RH • corrosive atmospheres, e.g. halogenides, sulphurous or nitrous gases, acid or alkaline solutions, etc. • environments containing oil and grease |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |