| 数据搜索系统,热门电子元器件搜索 |
|
R7I4DECT-1-DC32A-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R7I4DECT-1-DC32A-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 7 page ![]() MODEL: R7I4DECT-1-DC32A R7I4DECT-1-DC32A SPECIFICATIONS ES-7779-J Rev.1 Page 2/7 http://www.m-system.co.jp/ 8 A Rated output current: 0.2 A per point, 3.2 A per common Residual voltage: ≤ 1.2 V Leakage current: With wire breakdown detection: ≤ 0.7 mA Without wire breakdown detection: ≤ 0.1 mA ON delay: ≤ 0.2 msec. OFF delay: ≤ 0.5 msec. Overload current protection function: Turns OFF the outputs when overcurrent is detected Overheat protection function: Turns OFF the outputs when overheat is detected Diagnostic function: When the overcurrent, overheat and open load (disconnection) are detected, notifies to the status bit of upper input area. Refer to the users manual for details Note: Status is disabled with option code: /D1 (without wire breakdown detection). (When driving an inductive load, connect a diode in parallel with the load.) INSTALLATION Current consumption •DC at 24 V DC: Approx. 55 mA Operating temperature: -10 to +55°C (14 to 131°F) Storage temperature: -20 to +65°C (-4 to +149°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface or DIN rail (35 mm rail) Weight: 180 g (0.40 lb) PERFORMANCE Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (output or sensor excitaion toEtherCAT or FE to power) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581 FUNCTIONS ■ WIRE BREAKDOWN DETECTION The function to notifies to the status bit of upper input area in case of open load (disconnection) of discrete output is detected. Connect output load under 10 kΩ. Pull-down resister is mounted to detect disconnection so weak leakage current flows even when the output is OFF. Status bit is disabled and pull-down resister is not mounted with option code: /D1 (withourt wire breakdown detection). PC CONFIGURATOR The following parameters can be set with using PC Configurator Software (model: R7CFG) Refer to the users manual for the R7CFG for detailed operation of the software program. ■ CHANNEL INDIVIDUAL SETTING PARAMETER SETTING RANGE DEFAULT Unused setting (output only) CH enabled, CH disabled CH enabled ■ CHANNEL BATCH SETTING PARAMETER SETTING RANGE DEFAULT Output at communication error Output hold, Output clear Output hold |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |