| 数据搜索系统,热门电子元器件搜索 |
|
RZMS-U9T-R 数据表(PDF) 9 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
RZMS-U9T-R 数据表(HTML) 9 Page - M-System Co.,Ltd. |
|
9 / 12 page ![]() MODEL: RZMS-U9 RZMS-U9 SPECIFICATIONS ES-7605 Rev.13 Page 9/12 http://www.m-system.co.jp/ CONNECTION DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. RS-232-C T3 T4 T2 T1 T7 T6 T5 Term. Resist. Network Interface Isolated Multi-output Power Circuit + – Shielded Twisted-pair Cable To Other I/O Modules Jumper *2 FG U (+) V (–) POWER JACK CONFIGURATOR INPUT 2 1A 1B 1C INPUT 1 2A 2B 2C Analog Input Circuit 1 Analog Input Circuit 2 INPUT 4 3A 3B 3C INPUT 3 4A 4B 4C Analog Input Circuit 3 Analog Input Circuit 4 INPUT 6 5A 5B 5C INPUT 5 6A 6B 6C Analog Input Circuit 5 Analog Input Circuit 6 INPUT 8 7A 7B 7C INPUT 7 8A 8B 8C Analog Input Circuit 7 Analog Input Circuit 8 INPUT 10 9A 9B 9C INPUT 9 10A 10B 10C Analog Input Circuit 9 Analog Input Circuit 10 INPUT 12 11A 11B 11C INPUT 11 12A 12B 12C Analog Input Circuit 11 Analog Input Circuit 12 TRIGGER INPUT ALM ALM ALARM OUTPUT TRG+ TRG– Isolated Alarm Output Isolated Trigger Input Micro Processor Based Controller *1 C B A ext. wire + – + – C B A C B A C B A ext. wire – + – + – + C B A + – A B B 3 2 1 max. min. ■ DC INPUT ■ T/C INPUT • Upscale / No Burnout ■ T/C INPUT • Downscale Burnout ■ RTD INPUT ■ POTENTIOMETER INPUT *1 Input Connection Examples *2 When the device is located at the end of a transmission line via twisted-pair cable, (when there is no cross-wiring), close across the terminal T2 – T3 with the attached jumper pin (or with a leadwire). When the device is not at the end, remove the jumper pin. Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: In order to protect the RZMS-U9 module and connected devices in connecting/disconnecting Modbus cable or the configurator cable, be sure to earth FG terminals of the RZMS-U9 and the connected device to a most stable earth point in the environment. Grounding is also effective to eliminate problems caused by noises. Be careful to eliminate noise as much as possible by e.g. using shielded cables. The smaller is common mode voltage (DC and AC) between C terminals and between C and FG, the better is measuring accuracy. Connecting between C terminals and if possible to FG will yield the best accuracy. Resistor modules (model: REM3-250) can be connected to 1A through 12C terminals to convert current inputs into voltage. However, it is not recommended when TC inputs are mixed because the heat developed on and around the REM3 affects the cold junction compensation performance. We recommend that REM3 be connected on a separate terminal board. When the internal temperature sensors are used for CJC, temperature imbalance around the terminal block affects greatly the CJC accuracy. In order to minimize such imbalance, do not use wires of large diameter which has large heat dissipation. Be sure to close the terminal cover. Do not expose the module directly in the line of wind from a cooling fan. Two-wire RTD can be used by closing across B and C terminals. Be sure to compensate wire resistance by PC Configurator Software. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |