| 数据搜索系统,热门电子元器件搜索 |
|
SC210 数据表(PDF) 5 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
SC210 数据表(HTML) 5 Page - M-System Co.,Ltd. |
|
5 / 14 page ![]() MODEL: SC210 SC210 SPECIFICATIONS ES-6340 Rev.18 Page 5/14 http://www.m-system.co.jp/ INSTALLATION Power input ∙AC: Control module ≤ 25 VA at 100 V AC ≤ 40 VA at 240 V AC Backup module ≤ 10 VA at 100 V AC ≤ 15 VA at 240 V AC •DC Control module: ≤ 650 mA Backup module: ≤ 150 mA Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 5 to 90 %RH (non-condensing) Mounting: Panel flush mounting (high-density mounting in horizontal direction) Weight: Approx. 2.0 kg (4.41 lb) for 300 mm depth type Approx. 2.5 kg (5.51 lb) for 400 mm depth type PERFORMANCE Accuracy DC input: ±0.1 % ±1 digit Thermocouple input: ±1℃ ±1 digit ±2℃ ±1 digit for B, R, S, C and PR RTD input: ±1℃ ±1 digit Potentiometer input: ±0.2 % ±1 digit DC output: ±0.1 % Precision resistor module (REM4): ±0.1 % Cold junction compensation: ±2°C at 25°C ±10°C ±4°C for S, R and PR Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) DC input: ±0.015 %/°C (±0.008 %/°F) Thermocouple input: ±0.015 %/°C (±0.008 %/°F) RTD input: ±0.015 %/°C (±0.008 %/°F) Potentiometer input: ±0.015 %/°C (±0.008 %/°F) DC output: ±0.015 %/°C (±0.008 %/°F) Precision resistor module (REM4): ±0.015 %/°C (±0.008 %/°F) Line voltage effect: ±0.1 % over voltage range Calendar clock accuracy: Monthly deviation 3 minutes at 25°C RAM memory duration in power failure for hot start: 10 minutes assured Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (Pv1 or supply output to Pv2 or Ai1 or Ai2 or Ai3 or Ai4 to Di1 or Di2 or Di3 or Di4 or Di5 or Pi1 or Pi2 or Pi3 or Pi4 or Pi5 to Di6 or Pi6 to Mv1 to Mv2 or Mv2B or Ao1 or Ao2 to Do1 to Do2 or Do3 or Do4 or Do5 or Do6 to NestBus to Modbus-RTU to Modbus/TCP to power to backup module power to FG) 500 V AC @ 1 minute (Pv2 to Ai1 or Ai2 or Ai3 or Ai4) 500 V AC @ 1 minute (Mv2 or Mv2B to Ao1 or Ao2) 500 V AC @ 1 minute (Do2 to Do3 to Do4 to Do5 to Do6) 500 V AC @ 1 minute (Pv1 to supply output) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (contact output) Installation Category II (power) Pollution degree 2 Input or output to contact output – Basic insulation (300 V) Input or output to power - Reinforced insulation (300 V) RoHS Directive EN 50581 Protection against access to the terminal blocks: Finger protection (VDE 0660-514) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |