| 数据搜索系统,热门电子元器件搜索 |
|
SC210 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
SC210 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 14 page ![]() MODEL: SC210 SC210 SPECIFICATIONS ES-6340 Rev.18 Page 2/14 http://www.m-system.co.jp/ • Current output (4-20 mA) x 2 points, voltage output (1-5 V) x 2 points, relay or photo-MOSFET relay output x 5 points • RUN contact output (relay) x 1 point • I/O signals can be added with remote I/O modules connected via NestBus peer-to-peer communication • Computation cycle selectable between 50 msec. and 3 sec. (control cycle selectable between 1 and 64 times of the computation cycle) • Two PID function blocks • Advanced computation and sequence control functions • Auto-tuning function • Parameter input and changing with touch panel • Function parameter setting, list printing and data downloading/uploading available with Loop Configuration Builder Software (model: SFEW3E) • Short trend export (CSV), display parameter setting, saving and transfer with PC Configurator Software (model: SCCFG) • Control and supervision by SCADA software via Modbus TCP/IP or RTU communication • Backup module (applicable to Mv2 only) is incorporated for manual loading: MV output is automatically switched to manual control in case of control module abnormality • Independent power supply usable for the manual loader • Control module can be extracted at the front for replacement while MV output is maintained • Selectable housing depth for ease of using existing wires in replacement: 300 mm and 400 mm • Separable terminal block Typical Applications • Replacement of conventional controllers • Panel operation for small-scale instrumentation RELATED PRODUCTS • PC Configurator cable (model: COP-US) • Loop configuration builder software (model: SFEW3E Ver. 1.40 or later) • Infrared communication adaptor (model: COP-IRDA) • PC configurator software (model: SCCFG Ver.1.50 or later) Builder software and configurator software are downloadable at M-System’s web site. ACCESSORIES • Precision resistor module (model: REM4): 2 • Cold junction sensor: 2 • Mounting brackets: 2 • Connector adapter: 1 (included in Stereo jack type. The jack on the unit and the plug of PC Configurator cable (not included in the product) are different in size.) GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP55; ensured for the front panel of the unit independently mounted to a panel Connection Terminal screws: M3.5 screw terminals (torque 1.0 N·m) Terminal fixing screws: M4 screw terminals (torque 1.2 N·m) Backup module power supply terminal (option /M2, /R): Euro terminal block (applicable wire size: dia. 2.4 max., 0.5 – 2.5 mm2, stripped length 10 mm) Ethernet: RJ-45 Modular Jack Screw terminal Terminal screws: Nickel-plated steel (standard) or stainless steel Terminal fixing screws: Chrome-plated steel Housing material: Flame-resistant resin (gray), steel Isolation: Pv1 to Pv2 to supply output to Ai1 or Ai2 or Ai3 or Ai4 to Di1 or Di2 or Di3 or Di4 or Di5 or Pi1 or Pi2 or Pi3 or Pi4 or Pi5 to Di6 or Pi6 to Mv1 to Mv2 or Mv2B to Ao1 or Ao2 to Do1 to Do2 to Do3 to Do4 to Do5 to Do6 to NestBus to Modbus-RTU to Modbus/TCP to power to backup module power to FG PID control: Single loop, cascade, advanced Proportional band (P): 1 to 1000 % Integral time (I): 0.01 to 100 minutes Derivative time (D): 0.01 to 10 minutes Auto-tuning: Limit cycle method Alarm: PV high & low, deviation, rate of change Computation: 48 functions blocks available for arithmetic operations, time functions, signal selection, limit, alarm and other functions Sequence operation: Logic sequence and step sequence (max. 1068 commands) Computation cycle: 50 msec. to 3 sec. (control cycle selectable among 1, 2, 4, 8, 16, 32 and 64 times of the computation cycle) MV output range: -15 - +115 % Parameter setting: With touch panel or PC (Loop Configuration Builder Software model: SFEW3E) Self diagnostics: CPU monitoring with a watchdog timer RUN contact: OFF in error detected by diagnostic (including NestBus) Infrared communication: Transmission distance max. 0.2 meter (for use with the COP-IRDA) Short trend Storing interval: 1, 2, 5, 10, 20, 30 sec., 1, 2, 5, 10, 30, 60 min. Capacity: 400 points (display 200 points) ■ Display Display device: 4.3-inch TFT LCD |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |