| 数据搜索系统,热门电子元器件搜索 |
|
ES9023P 数据表(PDF) 13 Page - ESS Technology,Inc |
|
|
|||||||||||||||||||||||||||||
ES9023P 数据表(HTML) 13 Page - ESS Technology,Inc |
|
13 / 14 page ![]() April 6, 2015 CONFIDENTIAL ADVANCE INFORMATION Rev. 0.71 ES9023 Datasheet 13 ESS TECHNOLOGY, INC. 237 South Hillview Drive, Milpitas, CA 95035, USA Tel (408) 643-8800 • Fax (408) 643-8801 Table RPC-1 Classification reflow profile Profile Feature Pb-Free Assembly Preheat/Soak Temperature Min (Tsmin) Temperature Max (Tsmax) Time (ts) from (Tsmin to Tsmax) 150°C 200°C 60-120 seconds Ramp-up rate (TL to Tp) 3°C / second max. Liquidous temperature (TL) Time (tL) maintained above TL 217°C 60-150 seconds Peak package body temperature (Tp) For users Tp must not exceed the Classification temperature in Table RPC-2. For suppliers Tp must equal or exceed the Classification temperature in Table RPC-2. Time (tp)* within 5°C of the specified classification temperature (Tc), see Figure RPC-1 30* seconds Ramp-down rate (Tp to TL) °C / second max. Time 25 °C to peak temperature 8 minutes max. * Tolerance for peak profile temperature (Tp) is defined as a supplier minimum and a user maximum. Note 1: All temperatures refer to the center of the package, measured on the package body surface that is facing up during assembly reflow (e.g., live-bug). If parts are reflowed in other than the normal live-bug assembly reflow orientation (i.e., dead-bug), Tp shall be within ±2°C of the live-bug Tp and still meet the Tc requirements, otherwise, the profile shall be adjusted to achieve the latter. To accurately measure actual peak package body temperatures refer to JEP140 for recommended thermocouple use. Note 2: Reflow profiles in this document are for classification/preconditioning and are not meant to specify board assembly profiles. Actual board assembly profiles should be developed based on specific process needs and board designs and should not exceed the parameters in Table RPC-1. For example, if Tc is 260°C and time tp is 30 seconds, this means the following for the supplier and the user. For a supplier: The peak temperature must be at least 260°C. The time above 255°C must be at least 30 seconds. For a user: The peak temperature must not exceed 260°C. The time above 255°C must not exceed 30 seconds. Note 3: All components in the test load shall meet the classification profile requirements. Table RPC-2 Pb-Free Process – Classification Temperatures (Tc) Package Thickness Volume mm3, <350 Volume mm3, 350 to 2000 Volume mm3, >2000 <1.6 mm 260°C 260°C 260°C 1.6 mm – 2.5 mm 260°C 250°C 245°C >2.5 mm 250°C 245°C 245°C Note 1: At the discretion of the device manufacturer, but not the board assembler/user, the maximum peak package body temperature (Tp) can exceed the values specified in Table RPC-2. The use of a higher Tp does not change the classification temperature (Tc). Note 2: Package volume excludes external terminals (e.g., balls, bumps, lands, leads) and/or non-integral heat sinks. Note 3: The maximum component temperature reached during reflow depends on package thickness and volume. The use of convection reflow processes reduces the thermal gradients between packages. However, thermal gradients due to differences in thermal mass of SMD packages may still exist. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |