| 数据搜索系统,热门电子元器件搜索 |
|
E5CC-RX2DSM-800 数据表(PDF) 6 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CC-RX2DSM-800 数据表(HTML) 6 Page - Omron Electronics LLC |
|
6 / 36 page ![]() E5CC-800 6 Characteristics *1 The indication accuracy of K thermocouples in the -200 to 1300°C range, T and N thermocouples at a temperature of -100°C max., and U and L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°Cmax. is not specified. The indication accuracy of B thermocouples in the 400 to 800°Crange is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is ±0.3 of PV or ±3°C, whichever is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV or ±2°C, whichever is greater, ±1 digit max. *2 Ambient temperature: -10°C to 23°C to 55°C, Voltage range: -15% to 10% of rated voltage *3 K thermocouple at -100°C max.: ±10°C max. *4 “EU” stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is °C or °F. *5 The unit is determined by the setting of the Integral/Derivative Time Unit parameter. *6 Refer to information on maritime standards in Shipping Standards on page 31 for compliance with Lloyd's Standards. Indication accuracy (at the ambient temperature of 23°C) Thermocouple: ( ±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: ( ±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Influence of temperature *2 Thermocouple input (R, S, B, W, PL II): ( ±1% of PV or ±10°C, whichever is greater) ±1 digit max. Other thermocouple input: ( ±1% of PV or ±4°C, whichever is greater) ±1 digit max. *3 Platinum resistance thermometer: ( ±1% of PV or ±2°C, whichever is greater) ±1 digit max. Analog input: ( ±1%FS) ±1 digit max. CT input: ( ±5%FS) ±1 digit max. Influence of voltage *2 Input sampling period 50 ms Hysteresis Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) *4 Analog input: 0.01% to 99.99% FS (in units of 0.01% FS) Proportional band (P) Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) *4 Analog input: 0.1% to 999.9% FS (in units of 0.1% FS) Integral time (I) 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5 Derivative time (D) 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5 Proportional band (P) for cooling Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) *4 Analog input: 0.1% to 999.9% FS (in units of 0.1% FS) Integral time (I) for cooling 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5 Derivative time (D) for cooling 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5 Control period 0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Alarm setting range -1999 to 9999 (decimal point position depends on input type) Affect of signal source resistance Thermocouple: 0.1°C/ Ω max. (100 Ωmax.) Platinum resistance thermometer: 0.1°C/ Ω max. (10 Ω max.) Insulation resistance 20 M Ω min. (at 500 VDC) Dielectric strength 2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge) Vibration resistance 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions Malfunction 10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions Destruction Shock resistance 100 m/s2, 3 times each in X, Y, and Z directions Malfunction 300 m/s2, 3 times each in X, Y, and Z directions Weight Controller: Approx. 120 g, Mounting Bracket: Approx. 10 g Degree of protection Front panel: IP66, Rear case: IP20, Terminals: IP00 Memory protection Non-volatile memory (number of writes: 1,000,000 times) Standards Approved standards UL 61010-1, CSA C22.2 No. 611010-1 (evaluated by UL) Conformed standards EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *6 EMC EMI: EN61326 Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A Noise Terminal Voltage: EN 55011 Group 1, class A EMS: EN 61326 ESD Immunity: EN 61000-4-2 Electromagnetic Field Immunity: EN 61000-4-3 Burst Noise Immunity: EN 61000-4-4 Conducted Disturbance Immunity: EN 61000-4-6 Surge Immunity: EN 61000-4-5 Voltage Dip/Interrupting Immunity: EN 61000-4-11 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |