| 数据搜索系统,热门电子元器件搜索 |
|
MDEV-PROTO 数据表(PDF) 11 Page - Linx Technologies |
|
|
|||||||||||||||||||||||||||||
MDEV-PROTO 数据表(HTML) 11 Page - Linx Technologies |
|
11 / 23 page ![]() – – – – 16 17 7. The Set Module button adds the address and Permissions Mask to the list. If a current module is selected, then the Permissions can be updated. The Remove module button removes the selected module from the list. The Remove All Modules button removes all of the modules from the list. 8. The Interrupt Mask sets the conditions under which an interrupt is to be generated on the CMD_DATA_OUT line. The Message Select menu sets the type of message that triggers the interrupt when the Selected Message Ready box is checked. 9. The TX Power Level Source configures how the transmitter output power is set. It uses either the voltage on the LVL_ADJ line or the value in the box. The accepted range of values is –20 to +12. 10. The Transmitter Mode selection sets whether the module transmits command messages when a status line input is asserted or when it receives a software command. 11. The Receiver Mode selection turns the receiver on or off for power savings. If the module is set as an Initiating Unit only with all status lines as inputs, then the receiver is disabled by default. 12. The Status Line Direction selection sets how the status lines are configured as inputs and outputs. Either the C0 and C1 hardware lines are used to set them in groups of 4 or the Status Line Mask is used to set them individually. 13. The Latch Status Outputs selection configures how the latched or momentary operation for each status line output is set. Either the LATCH_EN hardware line is used to set all of the lines the same way or the Latch Mask is used to set the lines individually. 14. The Custom Data box enables a custom 2-byte value to be loaded into the module to be transmitted with each control message or Acknowledge with Data packet. 15. The Duty Cycle configuration sets the interval and Keep on times for automatically cycling power to the receiver. 16. The Module Identity box displays the module type, firmware version and serial number of the active module. 17. The Read All button reads all of the current configurations from the active module. 18. The Submit button writes all changes to the active module. 19. The Set Defaults button restores the active module to factory default conditions. The Command Set tab (Figure 17) allows specific commands to be written to the module. 1. The Command box shows the hexadecimal values that are written to the module. Values can be typed into the box or a command can be selected from the Commands menu. 2. The Response box shows the hexadecimal values that are returned from the module in response to a command. 3. The Commands drop-down menu shows all of the commands that are available for the active module (Figure 18). Selecting one of the commands from this menu automatically fills in the Command box. The values can be adjusted by typing in the box. 4 1 2 3 6 5 Figure 17: The Master Development System Software Command Set Tab Figure 18: The Master Development System Software Demo Command Set Tab Commands Menu |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |