| 数据搜索系统,热门电子元器件搜索 |
|
VPM-S500-R 数据表(PDF) 2 Page - CUI INC |
|
|
|||||||||||||||||||||||||||||
VPM-S500-R 数据表(HTML) 2 Page - CUI INC |
|
2 / 5 page ![]() cui.com CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY date 01/25/2022 │ page 2 of 5 INPUT parameter conditions/description min typ max units voltage 90 264 Vac frequency 47 63 Hz current at 90-264 Vac, full load 8 A inrush current at 230 Vac, full load, cold start 70 A input fuse Built-in ac fuse. A blown fuse usually indicates permanent damage to the power supply serviceable by factory only. power factor correction at 230 Vac, full load 0.98 OUTPUT parameter conditions/description min typ max units total regulation ±1 % transient response output voltage returns to within 1% in less than 2.5 ms for a 50% load change. Peak transient does not exceed 5%. overshoot turn-on and turn-off overshoot shall not exceed 5% over nominal voltage. start-up time at 230 Vac 1 s hold-up time at 80% load 20 ms adjustment range output user adjustable ±5 % remote sense designated as RS+ and RS- on CN3. Total voltage compensation for cable losses with respect to the main output. (NOT available for current sharing models.) remote on/off defined RSW on CN3, requiring low signal to inhibit output. LED display (LED 1) green - the power supply is operating normally. orange - when any protection occurs or RSW is low. power good designated as PG on CN3. This signal goes high 100~500 ms after the output reaches regulation. It goes low at least 1 ms before loss of regulation. current sharing designated as CSH on CN3, optional single wired for forced surrent sharing function and parallel up to 4 units within 10% accuracy at full load. current monitor designated as CMN on CN3 for for current sense for 0.5~3 Vdc to represent 0~100% output current. PROTECTIONS parameter conditions/description min typ max units input under voltage protection Power supply shuts down when ac input is under 80 ±5 Vac. When ac line reappears over 86 ±5 Vac, the power supply restarts automatically. over voltage protection shutdown and latches, ac input reset required to restart 130 % over current protection auto recovery 110 140 %Io short circuit protection continuous auto recovery upon removal of short Additional Resources: Product Page |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |