3 / 5 page ![]() cui.com CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY date 01/25/2022 │ page 3 of 5 SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage primary to secondary at 10 mA for 3 seconds primary to transformer core at 10 mA for 3 seconds primary to earth ground for at 10 mA 3 seconds 3,000 1,500 1,500 Vac Vac Vac safety approvals UL 60950-1 EMI/EMC EN 55022 Class B conducted/radiated, EN 61000-3-(2,3), EN 55024, IEC 61000-4-(2,3,4,5,6,8,11) leakage current at 264 VAC 2 mA grounding test allowable resistance measured when 25 A current is applied from the ground pin of the three prong plug to the farthest earthed connection point. 0.1 Ω RoHS compliant yes MTBF according to MIL-HBK-217F at 30°C 100,000 hours ENVIRONMENTAL parameter conditions/description min typ max units operating temperature derating linearly at 2.5% from 50~70°C 0 70 °C storage temperature -20 85 °C operating humidity non-condensing 5 90 %RH storage humidity non-condensing 5 95 %RH Additional Resources: Product Page |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|