13 / 17 page ![]() 13/17 TDA7575PD The information related to the outputs status is read and memorized at the end of the current pulse top. The acquisition time is 100 ms (typ.). No audible noise is generated in the process. As for SHORT TO GND / Vs the fault-detection thresholds remain unchanged from 26 dB to 12 dB gain setting. They are as follows: Concerning SHORT ACROSS THE SPEAKER / OPEN SPEAKER, the threshold varies from 26 dB to 12 dB gain setting, since different loads are expected (either normal speaker's impedance or high impedance). The values in case of 26 dB gain are as follows: If the Line-Driver mode (Gv= 12 dB and Line Driver Mode diagnostic = 1) is selected, the same thresholds will change as follows: b) PERMANENT DIAGNOSTICS. Detectable conventional faults are: – SHORT TO GND – SHORT TO Vs – SHORT ACROSS THE SPEAKER The following additional features are provided: – OUTPUT OFFSET DETECTION The TDA7575PD has 2 operating statuses: 1) RESTART mode. The diagnostic is not enabled. Each audio channel operates independently from each oth- er. If any of the a.m. faults occurs, only the channel(s) interested is shut down. A check of the output status is made every 1 ms (fig. G). Restart takes place when the overload is removed. 2) DIAGNOSTIC mode. It is enabled via I2C bus and self activates if an output overload (such to cause the in- tervention of the short-circuit protection) occurs to the speakers outputs . Once activated, the diagnostics pro- cedure develops as follows (fig. H): – To avoid momentary re-circulation spikes from giving erroneous diagnostics, a check of the output status is made after 1ms: if normal situation (no overloads) is detected, the diagnostic is not per- formed and the channel returns back active. – Instead, if an overload is detected during the check after 1 ms, then a diagnostic cycle having a du- ration of about 100 ms is started. – After a diagnostic cycle, the audio channel interested by the fault is switched to RESTART mode. The D02AU1341 S.C. to GND x S.C. to Vs 0V 1.8V VS-1.5V VS x Normal Operation 1.2V VS-0.9V S.C. across Load x Open Load 0V 1.5 Ω 70 Ω Infinite x Normal Operation 0.5 Ω 130 Ω D01AU1254 D01AU1252 S.C. across Load x Open Load 0 Ω 4.5 Ω 200 Ω infinite x Normal Operation 1.5 Ω 400 Ω |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |