49 / 264 page ![]() DS12308 Rev 4 49/264 L9788 Watchdog 263 Figure 18. WDA state flow Each time the watchdog error counter is EC > 7 counter PWR_CNT counter increases. When this counter is PWR_CNT=7 and a further error occurs, the power-latch will be terminated if KEY_IN is low. The PWR_CNT-counter is not cleared when EC <7. PWR_CNT-counter is cleared when EC < 5 or by RST_UV. The monitoring module works independently of the controller functionality. The monitoring module generates various questions, which the controller must fetch and correctly respond to within a defined time window. The monitoring module checks whether the response is returned in a time window and if the response is fully correct. The question is a 4-bit word. This 4-bit word can be fetched by the controller using a read access to register WDA REQULO. The monitoring module also calculates the expected correct response, which is compared to the actual response from the controller. The response is a 32-bit word consisting of the 4 bytes RESP_BYTE3, RESP_BYTE2, RESP_BYTE1 and RESP_BYTE0. The 4 bytes are sent to the monitoring module via MSC in the order RESP_BYTE3 - RESP_BYTE2 - RESP_BYTE1 - RESP_BYTE0 using four times the command WDA_RESP - once for each answer byte. The monitoring cycle phase is initialized by (the end of) writing of RESP_BYTE0 (least significant response byte) or by a write access to the RESPTIME register. The cycle starts with a variable wait time (response time, set by register RESPTIME), followed by a fixed time window. When a monitoring cycle ends (the end of the fixed time window has been reached) a new monitoring cycle is started automatically. A correct response within the time window (at a response time > 0 ms) decreases an ERROR COUNTER by one. An incorrect response, a response outside the time window or response time = 0 ms leads to the incrementing of the ERROR COUNTER by one. Power Down Safety loads = disabled WDA pin = Low Power On and Reset release Configure WDA Time Window and Request first Query Write Answer Answer0 Answer1 Right Answer ? Decrement ERR_CNT yes ERR_CNT < 5 Safety Loads = Enabled WDA pin = High RST_CNT = 0 yes WDA Sequencer starts WDA Time Reference no no yes Increment RST_CNT no ERR_CNT > 7 KEY OFF? no yes RST_CNT = 0 PWR_CNT = 0 yes Generate Reset Drive RST pin to Low PWR_CNT > 7 Increment ERR_CNT no Increment PWR_CNT (max 7) yes INIT_WDR=1 ? yes no Generate next Query no GADG2511161203PS RST_CNT =7 (Typ 64 kHz +/-5%) ERR_CNT = 6 PWR_CNT = 0 Request for Query |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |