| 数据搜索系统,热门电子元器件搜索 |
|
MHP27005S/ES 数据表(PDF) 3 Page - Interpoint Corporation Company |
|
|
|||||||||||||||||||||||||||||
MHP27005S/ES 数据表(HTML) 3 Page - Interpoint Corporation Company |
|
3 / 7 page ![]() MHP270 SERIES 65 WATT DC/DC CONVERTERS Electrical Characteristics: 25°C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified. DUAL OUTPUT MODELS1 MHP27005D MHP27012D MHP27015D PARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS OUTPUT VOLTAGE +VOUT 4.95 5.00 5.05 11.88 12.00 12.12 14.85 15.00 15.15 VDC –VOUT 4.95 5.00 5.05 11.88 12.00 12.12 14.85 15.00 15.15 OUTPUT CURRENT2 VIN = 160 TO 400 VDC 0 ±5 8.0 0 ±2.5 4.0 0 ±2.16 3.46 A OUTPUT POWER2 VIN = 160 TO 400 VDC 0 — 50 0 — 60 0 — 65 W OUTPUT RIPPLE 10 kHz - 2 MHz VOLTAGE ± VOUT — 50 100 — 50 125 — 50 125 mV p-p LINE REGULATION VIN = 160 TO 400 VDC ±VOUT — — 100 — — 120 — — 150 mV LOAD REGULATION3 NO LOAD TO FULL ±VOUT — — 100 — — 120 — — 150 mV CROSS REGULATION4 EFFECT ON –VOUT — — 1000 — — 800 — — 750 mV INPUT VOLTAGE CONTINUOUS 160 270 400 160 270 400 160 270 400 VDC TRANSIENT5 50 ms 0 — 450 0 — 450 0 — 450 V INPUT CURRENT NO LOAD — — 20 — — 20 — — 20 mA INHIBITED - INH1 — — 10 — — 10 — — 8 mA INHIBITED - INH2 — — 15 — — 15 — — 15 INPUT RIPPLE CURRENT 10 kHz - 10 MHz — — 45 — — 45 — — 45 mA p-p EFFICIENCY BALANCED LOAD 74 — — 81 — — 82 — — % LOAD FAULT6 POWER DISSIPATION SHORT CIRCUIT — — 8 — — 7.5 — — 19 W VOUT — — ±2.0 — — ±1.0 — — ±1.5 V STEP LOAD 50 %–100% LOAD7 RESPONSE ± VOUT TRANSIENT — — 300 — — 900 — — 900 mV pk RECOVERY8 — — 500 — — 500 — — 500 µs Notes 1. Share operation not characterized for dual outputs. 2. Up to 80% of the total output power (current) is available from either output providing the opposite output is carrying 20% of the power (current) in use. 3. Assumes balanced loads on the outputs. 4. Effect on the negative output from 50%/50% loads to 70%/30% or 70%/30% loads. 5. Unit will shut down above approximately 425V but will be undamaged and will restart when voltage drops into normal range. 6. Indefinite short circuit protection not guaranteed above 125°C case. 7. Second output at 50% 8. Recovery time is measured from application of the transient to point at which Vout is within 1% of final value. RL 1 2 3 4 5 6 REMOTE SENSE CONNECTION 12 11 10 9 8 7 – + 270 V – + Inhibit Sync In Positive Input Input Common INH2 INH1 Sync Out Sync In Share N/C Pos. Sense Sense Return Output Common Positive Output FIGURE 1: SENSE CONNECTIONS SINGLE OUTPUT MODELS CONNECTION DIAGRAM - SENSE 3 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |