20 / 35 page ![]() Figure 21. TB pin: (external configuration: dynamic blanking time and valley synch) Figure 22. TB pin: external configuration: (only valley synch) Figure 23. TB pin: external configuration (only dynamic blanking time ) Figure 24. TB pin: external configuration (no dynamic blanking time nor valley synch) 5.10 Overload and short-circuit protection To manage an overload or a short-circuit condition, an internal up-down counter is incremented or decremented with an internal clock, if the FB pin voltage is, respectively, above or below the upper saturation limit VFBH. If the overload/short-circuit event persists for a time greater than TOVL (50 ms typical value), the switching is inhibited and VDD is recycled between VDD_RESTART and VDD_ON by the periodical activation of the HV current source. After TRESTART from protection tripping, the IC restarts switching with soft-start as soon as VDD is recharged to VDD-ON. After soft-start (during which the overload counter is disabled), if overload is still present, the switching activity is disabled again as previously described, otherwise it resumes normal operation. If the overload/short-circuit event persists for a time smaller than TOVL, the counter is decremented cycle-by-cycle down to zero and the IC is not stopped. This fault management ensures low repetition rate restart attempts, so that the converter works safely with extremely low power throughput and avoids the IC overheating in case of repeated overload events, and a prompt resumption of normal operation at fault removal. In case of transformer saturation, short-circuit of secondary side rectifier or deep CCM, a further protection feature named OCP_LEB is embedded: if the drain current value is higher than IOCP_LEB at the end of LEB time for two subsequent cycles the VIPERGAN65 shuts down for TSD-REST seconds and performs a new startup. In case of VDD clamp activation with a current sunk from the pin higher than IDD-CL (26 mA typ.) and for a time duration higher than TDD-CL (100 us typ.), the IC is shut down then restart after VDD recycling. VIPERGAN65 Overload and short-circuit protection DS14005 - Rev 2 page 20/35 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |