| 数据搜索系统,热门电子元器件搜索 |
|
AS5045 数据表(PDF) 22 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS5045 数据表(HTML) 22 Page - ams AG |
|
22 / 24 page ![]() AS5045 12-BIT PROGRAMMABLE MAGNETIC ROTARY ENCODER Revision 1.5 www.austriamicrosystems.com Page 22 of 24 14.5 Internal Timing Tolerance The AS5045 does not require an external ceramic resonator or quartz. All internal clock timings for the AS5045 are generated by an on-chip RC oscillator. This oscillator is factory trimmed to ±5% accuracy at room temperature ( ±10% over full temperature range). This tolerance influences the ADC sampling rate and the pulse width of the PWM output: Absolute output; SSI interface: A new angular value is updated every 400µs (typ.) PWM output: A new angular value is updated every 400µs (typ.). The PWM pulse timings Ton and Toff also have the same tolerance as the internal oscillator (see above). If only the PWM pulse width Ton is used to measure the angle, the resulting value also has this timing tolerance. However, this tolerance can be cancelled by measuring both Ton and Toff and calculating the angle from the duty cycle (see section 6): () 1 4097 − + ⋅ = off on on t t t Position 14.6 Temperature 14.6.1 Magnetic Temperature Coefficient One of the major benefits of the AS5045 compared to linear Hall sensors is that it is much less sensitive to temperature. While linear Hall sensors require a compensation of the magnet’s temperature coefficients, the AS5045 automatically compensates for the varying magnetic field strength over temperature. The magnet’s temperature drift does not need to be considered, as the AS5045 operates with magnetic field strengths from ±45…±75mT. Example: A NdFeB magnet has a field strength of 75mT @ –40°C and a temperature coefficient of -0.12% per Kelvin. The temperature change is from –40° to +125° = 165K. The magnetic field change is: 165 x -0.12% = -19.8%, which corresponds to 75mT at –40°C and 60mT at 125°C. The AS5045 can compensate for this temperature related field strength change automatically, no user adjustment is required. 14.7 Accuracy over Temperature The influence of temperature in the absolute accuracy is very low. While the accuracy is ≤ ±0.5° at room temperature, it may increase to ≤±0.9° due to increasing noise at high temperatures. 14.7.1 Timing Tolerance over Temperature The internal RC oscillator is factory trimmed to ±5%. Over temperature, this tolerance may increase to ±10%. Generally, the timing tolerance has no influence in the accuracy or resolution of the system, as it is used mainly for internal clock generation. The only concern to the user is the width of the PWM output pulse, which relates directly to the timing tolerance of the internal oscillator. This influence however can be cancelled by measuring the complete PWM duty cycle instead of just the PWM pulse (see 14.5). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |