| 数据搜索系统,热门电子元器件搜索 |
|
H7CC-R11D 数据表(PDF) 49 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CC-R11D 数据表(HTML) 49 Page - Omron Electronics LLC |
|
49 / 66 page ![]() H7CC-R @ 49 Operating Procedures Parameters can be set with the operation keys on the front panel. Refer to the following for the detailed procedure. Step1 (AMD compatible) amd The H7CC-R @ is a Counter that contains more than one functional counter. When using the Counter in any mode other than the default mode, use the following chart to enter Configuration Selection Mode and set the functions that are suitable to the application. (Default mode: Tachometer) (Tachometer) Select the function using the UP1 Key (DW1 Key). (H7CC-R11 @ only) taco func UP1+UP6 or DW1+DW6 (Press and hold for 2 s) Run mode Power ON Configuration selection mode • Set the decimal point position using the UP1 Key (DW1 Key). Decimal point position (DP) (No decimal point) (One digit after decimal point) (Two digits after decimal point) (Three digits after decimal point) 10khz cnts *1. In the case of the -R11W@ type, set the tachometer output mode 1 or 2 with the UP or DOWN Key. *2 *1 UP1+UP3 or DW1+DW3 (Press and hold for 2 s) UP1+UP3 or DW1+DW3 (Press and hold for 2 s) Run mode Power ON *1 Function setting mode * Use UP1+UP3 to move up and DW1+DW3 to move down * (10 ms) (1 ms) * * * Step2 * (99.999) (1.000) (0.001) To next page From next page Prescale value (PSCL) Parameters are set with the operation keys on the front panel. Change to Function Setting Mode. (LO) (HI) (LO) (HI) (30 Hz) (10 kHz) The characters displayed in reverse video are the default settings. In the function setting mode, the status indicator of the keys that can be set lights up. (Example) In the case of the prescale value (PSCL) A value from 0.001 to 99.999 can be set, and therefore, the status indicator of the UP1 Key to UP5 Key (DW1 Key to DW5 Key) lights up. hilo 30hz area hihi 10ms 1ms lolo lo hi lo hi 0.001 99.999 1.000 (AREA) (HI-HI) (LO-LO) (HI-LO) In the case of AMD compatibility *1 If the mode is switched to the function setting mode during operation, operation will continue. *2 Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode. Tachometer output mode 1 (TO1M) Tachometer output mode 2 (TO2M) Tachometer output mode (TOTM) • Set the tachometer output mode using the UP1 Key (DW1 Key). Counting speed (CNTS) • Set the counting speed using the UP1 Key (DW1 Key). Note: The indicator display is disabled during the upper or lower limit setting. 1000 pscl For details on operations in run mode, refer to page 55. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |