31 / 66 page ![]() 31 H7CC-A @ tachometer Setting Procedure Guide Tachometer Operation Step1 The H7CC-AW @/AU@ is a Counter that contains more than one functional counter. At the time of delivery *, the H7CC is set to the 1-stage preset counter configuration or 2-stage preset counter configuration. Enter configuration selection mode using the following chart and set the tachometer mode. twn (1-stage preset counter) (2-stage preset counter) (Total and preset counter) (Batch counter) (Dual counter) (Twin counter) (Tachometer) Select the function using the UP1 Key (DW1 Key) . UP1+UP6 or DW1+DW6 (Press and hold for 2 s) UP1+UP6 or DW1+DW6 (Press and hold for 2 s) Run mode Power ON Configuration selection mode Model Default mode H7CC-AW H7CC-AU 2-stage preset counter 1-stage preset counter * Table Default Modes and Selectable Functions Any mode Any mode Selectable mode *1 *2 *1 UP1+UP3 or DW1+DW3 (Press and hold for 2 s) UP1+UP3 or DW1+DW3 (Press and hold for 2 s) Run mode Power ON Function setting mode * Use UP1+UP3 to move up and DW1+DW3 to move down Step2 * * * * * * (99.999) (1.000) (0.001) To next page From next page (30 Hz) (10 kHz) (LO) (HI) (LO) (HI) (No decimal point) (One digit after decimal point) (Two digits after decimal point) (Three digits after decimal point) (Four digits after decimal point) Prescale value (PSCL) Parameters are set with the operation keys on the front panel. Change to Function Setting Mode. The characters displayed in reverse video are the default settings. In the function setting mode, the status indicator of the keys that can be set lights up. (Example) In the case of the prescale value (PSCL) A value from 0.001 to 99.999 can be set, and therefore, the status indicator of the UP1 Key to UP5 Key (DW1 Key to DW5 Key) lights up. hilo 30hz area hihi lolo f1 f2 f3 f4 f5 lo hi lo hi --.---- 0.001 99.999 1.000 (AREA) (HI-HI) (LO-LO) (HI-LO) (Error) (Absolute ratio) (1 input) (2 inputs) (Error ratio) Counting speed (CNTS) Tachometer output mode (TOTM) Decimal point position (DP) Tachometer input mode (TINM) • Set the tachometer input mode using the UP1 Key (DW1 Key). • Set the tachometer output mode using the UP1 Key (DW1 Key). • Set the counting speed using the UP1 Key (DW1 Key). Note: Even if 10 kHz is selected when the tachometer input mode is F2 to F5, the counting speed will be 5 kHz. Note: The indicator display is disabled during the upper or lower limit setting. *1 Set tachometer output modes 1 and 2 using the UP1 Key (DW1 Key). Tachometer output mode 1 (TO1M) Note: Displayed only when the tachometer input mode is F2 (2 inputs). Tachometer output mode 2 (TO2M) • Set the decimal point position using the UP1 Key (DW1 Key). Note: “--.----“ will be displayed when pulse width measurement is set or when the display unit is set to seconds. *1 If the mode is switched to the function setting mode during operation, operation will continue. *2 Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode. 1000 pscl For details on operations and display in run mode, refer to page 37. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |