| 数据搜索系统,热门电子元器件搜索 |
|
BQ34Z100-R2 数据表(PDF) 6 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ34Z100-R2 数据表(HTML) 6 Page - Texas Instruments |
|
6 / 27 page ![]() 6.8 Electrical Characteristics: Low-Frequency Oscillator TA = –40°C to 85°C, 2.4 V < REG25 < 2.6 V; Typical Values at TA = 25°C and REG25 = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT f(LOSC) Operating frequency 32.768 kHz f(LEIO) Frequency error(1) (2) TA = 0°C to 60°C –1.5% 0.25% 1.5% TA = –20°C to 70°C –2.5% 0.25% 2.5% TA = –40°C to 85°C –4% 0.25% 4% t(LSXO) Start-up time(3) 500 μs (1) The frequency drift is included and measured from the trimmed frequency at VCC = 2.5 V, TA = 25°C. (2) The frequency error is measured from 32.768 kHz. (3) The startup time is defined as the time it takes for the oscillator output frequency to be ±3%. 6.9 Electrical Characteristics: High-Frequency Oscillator TA = –40°C to 85°C, 2.4 V < REG25 < 2.6 V; Typical Values at TA = 25°C and REG25 = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT f(OSC) Operating frequency 8.389 MHz f(EIO) Frequency error(1) (2) TA = 0°C to 60°C –2% 0.38% 2% TA = –20°C to 70°C –3% 0.38% 3% TA = –40°C to 85°C –4.5% 0.38% 4.5% t(SXO) Start-up time(2) 2.5 5 ms (1) The frequency error is measured from 2.097 MHz. (2) The startup time is defined as the time it takes for the oscillator output frequency to be ±3%. 6.10 Electrical Characteristics: Integrating ADC (Coulomb Counter) Characteristics TA = –40°C to 85°C, 2.4 V < REG25 < 2.6 V; Typical Values at TA = 25°C and REG25 = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT V(SR) Input voltage range, V(SRN) and V(SRP) V(SR) = V(SRN) – V(SRP) –0.125 0.125 V tSR_CONV Conversion time Single conversion 1 s Resolution 14 15 bits VOS(SR) Input offset 10 µV INL Integral nonlinearity error ±0.007% ±0.034% FSR(2) ZIN(SR) Effective input resistance(1) 2.5 MΩ Ilkg(SR) Input leakage current(1) 0.3 µA (1) Specified by design. Not tested in production. (2) Full-scale reference 6.11 Electrical Characteristics: ADC (Temperature and Cell Measurement) Characteristics TA = –40°C to 85°C, 2.4 V < REG25 < 2.6 V; Typical Values at TA = 25°C and REG25 = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VIN(ADC) Input voltage range 0.05 1 V tADC_CONV Conversion time 125 ms Resolution 14 15 bits VOS(ADC) Input offset 1 mV ZADC1 Effective input resistance (TS)(1) 8 MΩ ZADC2 Effective input resistance (BAT)(1) BQ34Z100-R2 not measuring cell voltage 8 MΩ BQ34Z100-R2 measuring cell voltage 100 KΩ BQ34Z100-R2 SLUSF37 – DECEMBER 2022 www.ti.com 6 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated Product Folder Links: BQ34Z100-R2 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |