20 / 38 page ![]() 6.4 FAULT indication The FAULT pin is an active low open drain output indicating fault conditions. This pin is activated when at least one of the following conditions occurs: • Junction over-temperature (TJX >TJSD) of one or more channels of the Process Stage or case shut-down protection (TC >TCSD) is active • Internal communication error. The communication error is intended as an internal data corruption event in the data transfer through isolation. In case of communication error, the outputs are initially kept in the previous status and then reset (turned off) at the first communication error during data transfer of the refresh signal 6.4.1 Junction overtemperature The thermal status of the device is updated during each transmission sequence between the two isolated stages. In SCM operation, when LOAD signal is high and SYNC one is low, the communication between the two stages is disabled. In this case the thermal status of the device cannot be updated, and the FAULT indication could be different to the actual status. In any case, the thermal protections of the channel outputs in the Process Stage are always operative. Figure 15. Thermal status update ISO808, ISO808-1 FAULT indication DS14169 - Rev 1 page 20/38 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |