| 数据搜索系统,热门电子元器件搜索 |
|
FT-R44Y 数据表(PDF) 22 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
FT-R44Y 数据表(HTML) 22 Page - List of Unclassifed Manufacturers |
|
22 / 28 page ![]() Digital Fiber Sensor FX-300 SERIES 160 Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS PRECAUTIONS FOR PROPER USE Cautions on sensor connection in cascade • When the units of the group A and the group B are connected in cascade as <Figure B> shown above, optical communications cannot be done. When the optical communications function is used, connect them as <Figure A> shown above. If the units cannot be placed as <Figure A>, the following measure 1 or 2 should be taken. 1 Affix the communication window seal of the accessory fiber amplifier protection seal ( FX-MB1) to the communication window of the FX-301(P) updated version unit or FX-305(P). 2 If the measure 1 described above cannot be taken, change the optical communications spec. of the group B units. • When the units in the group A and the group B shown in the table below are connected in cascade, connect them in cascade as <Figure A> shown below. Group B Group A <Figure A> Group A Group B <Figure B> Optical communications are possible Optical communications are impossible Group A FX-301(P): Previous version unit (Note 1), FX-301G(P)/B(P)/H(P), FX-41□(P), LS-401(P) (Note 2) Group B FX-301(P): Updated version unit (Note 1), FX-305(P) Notes: 1) For the difference between the updated version unit and the previous version unit, refer to “ A difference between the updated version unit and the previous version unit”. 2) When LS-401(P) is connected with the digital fiber amplifier in cascade, be sure to locate LS-401(P) at the left-most position (when viewed from the connector side). Notes: 1) FX-305(P); Output 1 operation indicator (Orange) 2) FX-305(P); Output 2 operation indicator (Orange) MODE indicator / L/D ON (Yellow) MODE indicator / TIMER (Yellow) MODE key Jog switch MODE indicator / PRO (Yellow) Digital display (Red) MODE indicator / ADJ (Yellow) MODE indicator / TEACH (Yellow) MODE indicator / RUN (Green) Operation indicator (Orange) (Note1) Stability indicator (Green)(Note2) Mount the amplifiers, one by one, on the 35 mm 1.378 in width DIN rail. Slide the amplifiers next to each other, and connect the quick- connection cables. Mount the optional end plates ( MS-DIN-E) at both the ends to hold the amplifiers between their flat sides. Tighten the screws to fix the end plates. • Change the communication specification of Group B according to the following procedures. Make sure to set the communication specification to “ (Group A communication specification)” or “ (Optical Communication Stop)”. Dismantling Cascading method How to change the communication specification of Group B Loosen the screws of the end plates. Remove the end plates. Slide the amplifiers and remove them one by one. 35 mm 1.378 in width DIN rail Sub unit Main unit Slide Sub cable (CN-71/72-C ) (Optional) Main cable (CN-73/74-C ) (Optional) End plate (MS-DIN-E) (Optional) Slide Notes: 4) When the communication specification is set to “ (Group A communication specification)”, make sure to tightly attach the products. Also make sure to take note of the following: • There are instances when the optical communication function cannot be used due to the usage environment, etc. • Do not perform batch channel loading or saving. Group B's Communication Specification Group A's Communication Specification Optical Communication Stop <Changing Procedure> Display [PRO4]. Long press the [Jog Switch] and [MODE key] at the same time. (Note 3) When you release the [Jog Switch] and [MODE key], the communication specification will be set and “PRO4” will be displayed. Notes: 3) Every time the [Jog Switch] and the [MODE key] is simultaneously long pressed, the display changes in this sequence: “ ”→“ ”→“ ”→“ ”→“ ”. Part description Operation procedure Power ON Communication self-check RUN TEACH ADJ L/D TIMER PRO Press MODE key Press MODE key Press MODE key Press MODE key Press MODE key Press MODE key [Teaching] (P.161) [Threshold value fine adjust] (P.162) [PRO mode] [Timer operation setting] (P.162) [Output operation setting] (P.162) • When the power supply is switched on, communication self-check is carried out and normal condition is displayed [MODE indicator / RUN (green)] lights up and the digital display shows the incident light intensity. • When the MODE key is pressed, the mode will change as shown in the following diagram. When Jog switch is pressed, the setting is confirmed. When MODE key is pressed for 2 sec., or more, the sensor returns to the ‘RUN’ mode. Cancellation is possible by pressing MODE key during setting. Refer to p.1458~ for general precautions and to the “PRO mode operation guide” on our website for details pertaining to operating instructions for the amplifier. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |