| 数据搜索系统,热门电子元器件搜索 |
|
FT-R44Y 数据表(PDF) 27 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
FT-R44Y 数据表(HTML) 27 Page - List of Unclassifed Manufacturers |
|
27 / 28 page ![]() 165 DigitalFiberSensorFX-300SERIES Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS PRECAUTIONS FOR PROPER USE Diagram of functions and settings The amplifier features and settings are generally classified into two main modes; the “NAVI mode” for items and settings that are frequently reconfigured, and the “PRO mode” that contains more detailed settings. NAVI mode PRO mode Sets output operation either Light-ON, or Dark-ON. L-ON / D-ON L/D Configures operation of the timer. Timer TIMER Allows various detailed settings to be configured, such as optical communications, save / load and other settings. Pro PRO Switches among response times. Response Time Change Configures timer operation. Timer Setting Sets hysteresis level. Hysteresis The “threshold value” can be set by utilizing either “2-point teaching”, “limit teaching”, or “full-auto teaching”. Teaching TEACH Allows fine adjustment of the “threshold value”. Adjust ADJ This indicates normal sensing operation. Run RUN PRO1 PRO2 PRO3 PRO4 PRO5 Shifts the “threshold value” by a certain percentage increment in “limit teaching”. Shift Permits selection of stability indicator response levels for changes in the range for lighting up. [excluding the FX-305(P)] Stability Allows selection of different content to be indicated in the digital display. Digital Display Setting Sets the viewing orientation of the digital display. Digital Display Inversion Sets the digital display to turn ON / OFF. ECO Mode Loads configuration setting from the data bank. Data Bank Load Saves configuration setting into the data bank. Data Bank Save Using optical communications, configuration settings from the main unit are copied to connected sub units all at once. Copy Using optical communication, configuration settings can be loaded from respective data banks all at once. Using optical communication, current configuration settings can be saved into respective data banks all at once. Remote Data Bank Load Remote Data Bank Save When using optical communication for carrying out copy / load / save operations all at once, this function allows optical communication to pass through the unit. Communication Change To Permit / Not to Permit Allows basic configuration information to be set in a single step, by inputting a 4-digit code. Code Allows fine adjustment of the “threshold value” to be directly performed during RUN mode. Adjust Lock All settings, except for data bank information, revert to factory settings. Reset The items that can be set are different for output 1 and output 2. Output 1 Output 2 Changes the light emitting amount selection setting. [ FX-301(P)(-HS), FX-305(P) only] LightEmittingAmountSelection Allows not to save the threshold value, by teaching via external input in EEPROM. [ FX-301(P), FX-305(P) only] Backup Switches the number of units for which interference prevention switching is enabled. * FX-305(P) only. Interference Prevention Switching Sets a threshold value for ON / OFF operation. Normal Mode Judges if set two threshold values are within the required range or not. This can be selected in 1-point / 2-point / 3-point teaching. Window Comparator Mode Sensing mode that cancels out slight changes in light intensity so that only sudden increases in incident light intensity are sensed. Rising Differential Mode PRO6 Trailing Differential Mode Sensing mode that cancels out slight changes in light intensity so that only sudden decreases in incident light intensity are sensed. Error Output Output when overcurrent occurs or when a communication error occurs from connected incompletely. Alarm Output Be used as alarm output when the threshold value for output 2 is linked to output 1 and the light amount drops. Verifies whether optical communications have been properly established. ( FX-301B/G/H only) Test * When the FX-305(P) is in window comparator mode, the “threshold value” can be set by either “1-point teaching”, “2-point teaching” or “3-point teaching”. AvailableonlyinFX-305(P) * The FX-301(P)-HS is not equipped with a PRO4 setting function. The FX-301(P)-HS is not equipped with a PRO4 setting function. * The 0-ADJ setting function equipped on the FX-301□ and FX-305(P) has been deleted since the production in May 2005. Refer to p.1458~ for general precautions and to the “PRO mode operation guide” on our website for details pertaining to operating instructions for the amplifier. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |