9 / 20 page ![]() 6.3 Control inputs The device is controlled through the IN+ and IN- logic inputs, in accordance with the truth table described in following Table 9 Table 9. STGAP2GS inputs truth table (applicable when device is not in UVLO or "safe state") Input pins Output pins IN+ IN- GON GOFF L L OFF ON H L ON OFF L H OFF ON H H OFF ON 6.4 Watchdog The isolated HV side has a watchdog function in order to identify when it is not able to communicate with LV side, for example because the VDD of the LV side is not supplied. In this case the output of the driver is forced in “safe state” until communication link is properly established again. 6.5 Thermal shutdown protection The device provides a thermal shutdown protection. When junction temperature reaches the TSD temperature threshold, the device is forced in “safe state”. The device operation is restored as soon as the junction temperature is lower than TSD-Thys. 6.6 Standby function In order to reduce the power consumption of both control interface and gate driving sides the device can be put in standby mode. In standby mode the quiescent current from VDD and VH supply pins is reduced to IQDDSBY and IQHSBY respectively, and the output remains in “safe state” (the output is actively forced low). The way to enter standby is to keep both IN+ and IN- high (“standby” value) for a time longer than tSTBY. During standby the inputs can change from the “standby” value. To exit standby, IN+ and IN- must be put in any combination different from the “standby” value for a time longer than tstbyfilt, and then in the “standby” value for a time t such that tWUP < t < tSTBY. When the input configuration is changed from the “standby” value the output is enabled and set according to inputs state after a time tawake. Figure 4. Standby state sequences Sequence to enter stand-by mode Sequence to exit stand-by mode IN+ & IN- Device status Output ACTIVE STAND-BY SAFE-STATE ACTIVE “stand-by” “stand-by” duration too short IN+ & IN- Device status Output ACTIVE STAND-BY SAFE-STATE ACTIVE ACTIVE ACTIVE “stand-by” “stand-by” “stand-by” “stand-by” duration too short duration too long “stand-by”: IN+ = IN- = HIGH is any different combination t = tSTBY t < tSTBY t = tSTBY t > tSTBY t = tawake t > tstbyflt t < tWUP tWUP< t < tSTBY STGAP2GS Control inputs DS14152 - Rev 1 page 9/20 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |