14 / 27 page ![]() Figure 9. Typical chronograms of TCPP02-M18 VBUS OCP ALARM HOLDING OCP switch open System OFF NORMAL SYSTEM ON Gate driver ON OFF TCPP ALARM HOLDING System is waiting recovery word up to 40 us OCP switch closed Over current VBUS current Note: • In case of VBUS OCP event, the TCPP02-M18 switches OFF all active functions except CC switches: – VCONN switches – VBUS gate driver – VCONN and VBUS discharge paths are activated • It is signaled to the user by several ways: – I2C corresponding state bits are cleared (i.e. VCONN1_ACK = 0, VCONN2_ACK = 0…) – I2C relevant OCP flag is set (FLGn_OCP_VBUS is the OCP event coming from VBUS switch for example) – Failure flag pin (FLGn) is active (i.e. in LowZ state) • After a delay of up to 40 µs, to recover, the below bit sequence has to be written and after recovery, the user can resume a start-up procedure: Table 13. VBUS OCP recovery bit sequence table Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 0 0 PM2 PM1 1 0 0 0 TCPP02-M18 VBUS analog current measurement and OCP DS13787 - Rev 4 page 14/27 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|