| 数据搜索系统,热门电子元器件搜索 |
|
ADL5501AKSZ-R7 数据表(PDF) 22 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADL5501AKSZ-R7 数据表(HTML) 22 Page - Analog Devices |
|
22 / 28 page ![]() ADL5501 Rev. 0 | Page 22 of 28 DRIFT OVER A REDUCED TEMPERATURE RANGE Figure 53 shows the error over temperature for a 1.9 GHz input signal. Error due to drift over temperature consistently remains within ±0.25 dB and only begins to exceed this limit when the ambient temperature goes above +25°C and below −10°C. For all frequencies using a reduced temperature range, higher measurement accuracy is achievable. 1.00 –1.00 –0.75 –0.50 –0.25 0 0.25 0.50 0.75 –25 –20 –15 –10 –5 0 5 10 15 INPUT (dBm rms) +85°C +70°C +50°C +35°C +25°C +15°C 0°C –10°C –25°C –40°C Figure 53. Typical Drift at 1.9 GHz for Various Temperatures 3 –3 –2 –1 0 1 2 –25 –20 –15 –10 –5 0 5 10 15 INPUT (dBm) Figure 54. Temperature Drift Distributions for 12 Devices at −40°C, +25°C, and +85°C vs. +25°C Linear Reference; Frequency 50 MHz; Supply 5.0 V 3 –3 –2 –1 0 1 2 –25 –20 –15 –10 –5 0 5 10 15 INPUT (dBm) Figure 55. Output Delta from +25°C Output Voltage for 12 Devices at −40°C and +85°C, Frequency 50 MHz, Supply 5.0 V OPERATION BELOW 100 MHZ The ADL5501 works at frequencies below 100 MHz, but exhibits slightly higher linearity error. Figure 54 shows the error distribution of 12 devices at 50 MHz over temperature. When compared to an ideal linear transfer function at ambient, the error of the ADL5501 over temperature remains within ±0.5 dB for the central 20 dB of the dynamic range. At the higher input power levels, the error grows as the response becomes nonlinear. Due to the repeatability of the performance from part to part, compensation can be applied to reduce the effects of temperature drift and linearity error. To detect larger dynamic ranges at lower frequencies, the transfer function at ambient can be calibrated, thus eliminating the linearity error. This technique is discussed in detail in the Calibration for Improved Accuracy section. Figure 55 shows that the dynamic range within ±0.5 dB error improves to 30 dB by using this method. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |