26 / 56 page ![]() December 13, 2005 Am29DL322D/323D/324D 25 again read array data with the same exception. See the Erase Suspend/Erase Resume Commands sec- tion for more information. The system must issue the reset command to return a bank to the read (or erase-suspend-read) mode if DQ5 goes high during an active program or erase opera- tion, or if the bank is in the autoselect mode. See the next section, Reset Command, for more information. See also Requirements for Reading Array Data in the Device Bus Operations section for more information. The Read-Only Operations table provides the read pa- rameters, and Figure 13 shows the timing diagram. Reset Command Writing the reset command resets the banks to the read or erase-suspend-read mode. Address bits are don’t cares for this command. The reset command may be written between the se- quence cycles in an erase command sequence before erasing begins. This resets the bank to which the sys- tem was writing to the read mode. Once erasure begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the bank to which the system was writing to the read mode. If the program command sequence is written to a bank that is in the Erase Suspend mode, writing the reset command retur n s that bank to the erase-sus- pe nd- read mode. Once pro gr a mming b egins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the se- quence cycles in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to the read mode. If a bank entered the autoselect mode while in the Erase Sus- pend mode, writing the reset command returns that bank to the erase-suspend-read mode. If DQ5 goes high during a program or erase operation, writing the reset command returns the banks to the read mode (or erase-suspend-read mode if that bank was in Erase Suspend). Autoselect Command Sequence The autoselect command sequence allows the host system to access the manufacturer and device codes, and determine whether or not a sector is protected. Table 14 shows the address and data requirements. This method is an alternative to that shown in Table 7, which is intended for PROM programmers and re- quires V ID on address pin A9. The autoselect command sequence may be written to an address within a ba nk that is either in the read or erase-suspend-read mode. The autoselect command may not be written while the device is actively pro- gramming or erasing in the other bank. The autoselect command sequence is initiated by first writing two unlock cycles. This is followed by a third write cycle that contains the bank address and the au- t o sel e ct comma nd. Th e bank th en ente r s the autoselect mode. The system may read at any ad- dress within the same bank any number of times without initiating another autoselect command sequence: ■ A read cycle at address (BA)XX00h (where BA is the bank address) returns the manufacturer code. ■ A read cycle at address (BA)XX01h in word mode (or (BA)XX02h in byte mode) returns the device code. ■ A read cycle to an address containing a sector ad- dress (SA) within the same bank, and the address 02h on A7–A0 in word mode (or the address 04h on A6–A-1 in byte mode) returns 01h if the sector is protected, or 00h if it is unprotected. (Refer to Ta- bles 3–6 for valid sector addresses). The system must write the reset command to return to the read mode (or erase-suspend-read mode if the bank was previously in Erase Suspend). Enter SecSi TM Sector/Exit SecSi Sector Command Sequence The SecSi Sector region provides a secured data area containing a random, sixteen-byte electronic serial number (ESN). The system can access the SecSi Sector region by issuing the three-cycle Enter SecSi Sector command sequence. The device continues to access the SecSi Sector region until the system is- sues the four-cycle Exit SecSi Sector command sequence. The Exit SecSi Sector command sequence returns the device to normal operation. The SecSi Sector is not accessible when the device is executing an Embedded Program or Embedded Erase algo- r i t h m . Ta bl e 14 show s th e ad dr ess a n d data requirements for both command sequences. See also “Se c S i TM (S ec ur ed Silico n) S e ctor F l a s h Memory Region” for further information. Byte/Word Program Command Sequence The system may program the device by word or byte, depending on the state of the BYTE# pin. Program- ming is a four-bus-cycle operation. The program command sequence is initiated by writing two unlock write cycles, followed by the program set-up com- mand. The program address and data are written next, which in turn initiate the Embedded Program algo- rithm. The system is not required to provide further controls or timings. The device automatically provides |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |