5 / 10 page ![]() Datasheet EE310 v2.7 / Modification rights reserved | 5 Technical Data Calculated Quantities from up to unit EE310-T1 EE310-T2 EE310-T5, T10 Dew point temperature Td -40 (-40) 60 (140) 80 (176) 100 (212) °C (°F) Frost point temperature Tf -40 (-40) 0 (32) 0 (32) 0 (32) °C (°F) Wet bulb temperature Tw 0 (32) 60 (140) 80 (176) 100 (212) °C (°F) Water vapour partial pressure e 0 (0) 200 (3) 500 (7.5) 1100 (15) mbar (psi) Mixing ratio r 0 (0) 425 (2900) 999 (9999) 999 (9999) g/kg (gr/lb) Absolute humidity dv 0 (0) 150 (60) 300 (120) 700 (300) g/m3 (gr/ft3) Specific enthalpy h 0 (0) 400 (180) 1000 (450) 2800 (1250) kJ/kg (BTU/lb) Measurands Relative Humidity (RH) Measuring range 0...100 %RH Accuracy1) incl. hysteresis, non-linearity and repeatability -15...+40 °C (5...104 °F), RH ≤90 % -15...+40 °C (5...104 °F), RH >90 % -25...+70 °C (-13...+158 °F) -40...+180 °C (-40...+356 °F) ± (1.3 + 0.3 % * mv) %RH ± 2.3 %RH ± (1.4 + 1 % * mv) %RH ± (1.5 + 1.5 % * mv) %RH mv = measured value Temperature dependence of electronics, typ. ±0.01 % RH / °C (0.0055 %RH / °F) Response time t90 with metal grid filter at 20 °C (68 °F) <15 s 1) Traceable to international standards, administrated by NIST, PTB, BEV,... The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement). For model T1 the accuracy data is valid only for air speed higher than 0.2 m/s. Temperature (T) Measuring range T1, wall mount T2, duct mount T5, remote probe T10, pressure tight probe T24, T only remote probe -40...+60 °C (-40...+140 °F) -40...+80 °C (-40...+176 °F) -40...+180 °C (-40...+356 °F) -40...+180 °C (-40...+356 °F) -80...+180 °C (-112...+356 °F) Accuracy1) Type T24 only ± ∆T [°C] T [°C] Temperature dependence of electronics, typ. ±0,001 °C / °C 1) Traceable to international standards, administrated by NIST, PTB, BEV,... The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement). For model T1 the accuracy data is valid only for air speed higher than 0.2 m/s. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |