数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

MASWSS0100 数据表(PDF) 2 Page - Tyco Electronics

部件名 MASWSS0100
功能描述  GaAs SP3T 2.5 V High Power Switch 0.1 - 3.0 GHz
PDF  3 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  MACOM [Tyco Electronics]
网页  http://www.macom.com
标志 MACOM - Tyco Electronics

MASWSS0100 数据表(HTML) 2 Page - Tyco Electronics

  MASWSS0100 Datasheet HTML 1Page - Tyco Electronics MASWSS0100 Datasheet HTML 2Page - Tyco Electronics MASWSS0100 Datasheet HTML 3Page - Tyco Electronics  
Zoom Inzoom in Zoom Outzoom out
 2 / 3 page
background image
GaAs SP3T 2.5 V High Power Switch
0.1 - 3.0 GHz
MASWSS0100
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V2
2
Parameter
Test Conditions
Units
Min.
Typ.
Max.
Insertion Loss
5
0.5 - 1.0 GHz
1.0 - 2.0 GHz
dB
dB
0.5
0.6
0.65
Isolation
0.5 - 1.0 GHz
1.0 - 2.0 GHz
dB
dB
23
25
20
Return Loss
0.5 - 2.5 GHz
dB
20
P.1dB
dBm
38
2
nd Harmonic
1.0 GHz, PIN = +34 dBm
dBc
-80
3
rd Harmonic
1.0 GHz, PIN = +34 dBm
dBc
-70
-65
Trise, Tfall
10% to 90% RF, 90% to 10% RF
nS
83
Ton, Toff
50% control to 90% RF
50% control to 10% RF
nS
94
Transients
In Band
mV
58
Control Current
2.5 V
µA
50
80
4. External DC blocking capacitors are required on all RF ports.
5. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 - 3 GHz.
Electrical Specifications: TA = 25°C, VC = 0 V / 2.5 V, Z0 = 50 Ω
4
V1
V2
V3
RFC–
RF1
RFC-
RF2
RFC -
RF3
1
0
0
On
Off
Off
0
1
0
Off
On
Off
0
0
1
Off
Off
On
Truth Table 6,7
6. State 0 = -5 V to +2.5 V, State 1 = -2.5 V to +5 V.
7. Differential voltage, V (state 1) - V (state 0), must be 2.5 V
minimum.
Qualification
Qualified
to
M/A-COM
specification
REL-201,
Process Flow –2.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
Functional Diagram



Html Pages

1 2 3


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com