4-212
RF2314
Rev A6 051025
Absolute Maximum Ratings
Parameter
Rating
Unit
Supply Voltage
8.0
V
Supply Current
32
mA
Storage Temperature
-40 to +150
°C
Parameter
Specification
Unit
Condition
Min.
Typ.
Max.
Operating Range
Overall Frequency Range
150
2500
MHz
Supply Voltage
2.7
6.0
V
Operating Current (ICC)2
5.7
9
mA
VCC=3V, Temp=27
oC
912.5
16
mA
VCC=5V, Temp=27
oC
Operating Ambient Temperature
-40
+85
C
3.0V Performance
Gain
16.6
dB
Freq=150MHz, VCC=3V, Temp=27
oC
Gain
11
12.9
14
dB
Freq=900MHz, VCC=3V, Temp=27
oC
Noise Figure
1.4
dB
OIP3
+3
+9
dBm
OP1dB
-4
-1
+1
dBm
Input Return Loss
10
dB
Output Return Loss
17
dB
Isolation
20
dB
Gain
6.5
7.9
9
dB
Freq=1900MHz, VCC=3V, Temp=27
oC
OIP3
+9
+12.5
dBm
OP1dB
-2
-0.5
+1
dBm
Gain
4
5.2
7
dB
Freq=2400MHz, VCC=3V, Temp=27
oC
OIP3
+11
+15.3
dBm
OP1dB
-1
+1.1
+3
dBm
5.0V Performance
Gain
19.1
dB
Freq=150MHz, VCC=5V, Temp=27
oC
Gain
12
14.2
16
dB
Freq=900MHz, VCC=5V, Temp=27
oC
Noise Figure
1.5
dB
OIP3
+14
+18
dBm
OP1dB
+3
+8
+11
dBm
Input Return Loss
13
dB
Output Return Loss
28
dB
Isolation
20
dB
Gain
6
8.2
10
dB
Freq=1900MHz, VCC=5V, Temp=27
oC
OIP3
+18
+22
dBm
OP1dB
+5
+6.7
+9
dBm
Gain
3.5
5.1
7
dB
Freq=2400MHz, VCC=5V, Temp=27
oC
OIP3
+19
+23
dB
OP1dB
+6
+7.9
+10
dB
Caution! ESD sensitive device.
RF Micro Devices believes the furnished information is correct and accurate
at the time of this printing. RoHS marking based on EUDirective2002/95/EC
(at time of this printing). However, RF Micro Devices reserves the right to
make changes to its products without notice. RF Micro Devices does not
assume responsibility for the use of the described product(s).