13 / 20 page ![]() 13 SP690T/S/R JAN 30-06 SP690T/S/R, 802/T/S/R, 804T/S/R, 805T/S/R Low Power Microprocessor Supervisory © 2006 Sipex Corporation The watchdog timer can also initiate a reset. Refer to the Watchdog Input section. The SP804T/S/R and SP805T/S/R active-HIGH RESET output is open drain and the inverse of the SP690T/S/R and SP802T/S/R RESET outputs. RESET is also triggered by a watchdog timeout. If WDI remains either high or low for a period that exceeds the watchdog timeout period (1.6 sec), RESET pulses low for 200mS. As long as RESET is asserted, the watchdog timer remains cleared. When RESET comes high, the watch- dog resumes timing and must be serviced within 1.6sec. If WDI is tied high or low, a RESET pulse is triggered every 1.8sec (t WD plus tRS). Reset Threshold The SP690T and SP805T devices are designed for 3.3V systems with a ±5% power-supply tolerance and a 10% system tolerance. Except for watchdog faults, reset will not assert as long as the power supply remains above 3.15V (3.3V - 5%). Reset is guaranteed to assert before the power supply falls below 3.0V. The SP690S and SP805S devices are designed for 3.3V ±10% power supplies. Except for watchdog faults, they are guaranteed not to assert reset as long as the supply remains above 3.0V (3.3V - 10%). Reset is guaranteed to assert before the power supply fails below 2.85V (V CC - 14%). The SP690R and SP805R devices are optimized for monitoring 3.0V ±10%powersupplies. Reset will not occur until V CC falls below 2.7V (3.0V - 10%), but is guaranteed to occur before the supply falls below 2.55V (3.0V - 15%). The SP802T/S/R and SP804T/S/R devices are respectively similar to the SP690T/S/R and SP805T/S/R devices with tightened reset and power-fail threshold tolerances. Watchdog Input The watchdog circuit monitors the µP's activity. If the µP does not toggle the watchdog input (WDI) within 1.6sec, a reset pulse is triggered. The internal 1.6sec timer is cleared by either a reset pulse or by a transition (LOW-to-HIGH or HIGH-to-LOW) at WDI. If WDI is tied HIGH or LOW, a RESET pulse is triggered every 1.8sec (t WD plus tRS). As long as reset is asserted, the timer remains cleared and does not count. As soon as reset is de-asserted, the timer starts counting. Unlike the 5V SP690A series, the watchdog function cannot be disabled. Power-Fail Comparator The power-fail comparator can be used as an under-voltage detector to signal the failing of a power supply (it is completely separate from the rest of the circuitry and does not need to be dedicated to this function). The PFI input is compared to an internal 1.25V. If PFI is less than V PFT, PFO goes low. The power-fail comparator turns off and PFO goes LOW when V CC falls below VSW on power-down. The power-fail comparator turns on as V CC crosses VSW on power-up. If the comparator is not used, connect PFI to ground and leave PFO unconnected. Backup-Battery Switchover In the event of a brownout or power failure, it may be necessary to preserve the contents of RAM. With a backup battery installed at V BATTERY, the devices automatically switch RAM to backup power when V CC fails. This family of µP supervisors (designed for 3.3V and 3V systems) doesn't always connect V BATTERY to VOUT when VBATTERY is greater than V CC. VBATTERY connects to VOUT (through a 15 Ω switch) when V CC is below VSW and V BATTERY is greater than VCC. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |