| 数据搜索系统,热门电子元器件搜索 |
|
03C8T6 数据表(PDF) 49 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
03C8T6 数据表(HTML) 49 Page - STMicroelectronics |
|
49 / 67 page ![]() STM32F103xx Electrical characteristics 49/67 5.3.15 Communications interfaces I 2C interface characteristics Unless otherwise specified, the parameters given in Table 34 are derived from tests performed under ambient temperature, fPCLK1 frequency and VDD supply voltage conditions summarized in Table 7. The STM32F103xx performance line I 2C interface meets the requirements of the standard I 2C communication protocol with the following restrictions: the I/O pins SDA and SCL are mapped to are not “true” open-drain. When configured as open-drain, the PMOS connected between the I/O pin and VDD is disabled, but is still present. In addition, there is a protection diode between the I/O pin and VDD. As a consequence, when multiple master devices are connected to the I 2C bus, it is not possible to power off the STM32F103xx while another I2C master node remains powered on. Otherwise, the STM32F103xx would be powered by the protection diode. The I 2C characteristics are described in Table 34. Refer also to Section 5.3.12: I/O port pin characteristics for more details on the input/output alternate function characteristics (SDA and SCL). Table 34. I2C characteristics Symbol Parameter Standard mode I2C(1) 1. Values based on standard I2C protocol requirement, not tested in production. Fast mode I2C(1)(2) 2. fPCLK1 must be higher than 2 MHz to achieve the maximum standard mode I 2C frequency. It must be higher than 4 MHz to achieve the maximum fast mode I2C frequency. Unit Min Max Min Max tw(SCLL) SCL clock low time 4.7 1.3 µs tw(SCLH) SCL clock high time 4.0 0.6 tsu(SDA) SDA setup time 250 100 ns th(SDA) SDA data hold time 0(3) 3. The maximum hold time of the Start condition has only to be met if the interface does not stretch the low period of SCL signal. 0(4) 4. The device must internally provide a hold time of at least 300ns for the SDA signal in order to bridge the undefined region of the falling edge of SCL. 900(3) tr(SDA) tr(SCL) SDA and SCL rise time 1000 20 + 0.1Cb 300 tf(SDA) tf(SCL) SDA and SCL fall time 300 20 + 0.1Cb 300 th(STA) Start condition hold time 4.0 0.6 µs tsu(STA) Repeated Start condition setup time 4.7 0.6 tsu(STO) Stop condition setup time 4.0 0.6 µs tw(STO:STA) Stop to Start condition time (bus free) 4.7 1.3 µs Cb Capacitive load for each bus line 400 400 pF |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |