24 / 36 page ![]() Short-circuit and overload protection VIPer53 - E 24/36 10 Short-circuit and overload protection A VCOMPovl threshold of about 4.35V has been implemented on the COMP pin. When VCOMP goes above this level, the capacitor connected on the TOVL pin begins to charge. When reaching typically VOVLth (4V), the internal MOSFET driver is disabled and the device stops switching. This state is latched because of to the regulation loop which maintains the COMP pin voltage above the VCOMPovl threshold. Since the VDD pin does not receive any more energy from the auxiliary winding, its voltage drops down until it reaches VDDoff and the device is reset, recharging the VDD capacitor for a new restart cycle. Note: If VCOMP drops below the VCOMPovl threshold for any reason during the VDD drop, the device resumes switching immediately. The device enters an endless restart sequence if the overload or short circuit condition is maintained. The restart duty cycle DRST is defined as the time ratio for which the device tries to restart, thus delivering its full power capability to the output. In order to keep the whole converter in a safe state during this event, DRST must be kept as low as possible, without compromising the real start-up of the converter. A typical value of about 10% is generally sufficient. For this purpose, both VDD and TOVL capacitors can be used to satisfy the following conditions: Equation 6 Equation 7 Refer to the previous start-up section for the definition of tss, and CVDD must also be checked against the limit given in this section. The maximum value of the two calculus will be adopted. All this behavior can be observed on Figure 8 on page 10. In Figure 10 on page 11 the value of the drain current Id for VCOMP = VCOMPovl is shown. The corresponding parameter IDmax is the drain current to take into account for design purposes. Since IDmax represents the maximum value for which the overload protection is not triggered, it defines the power capability of the power supply. C OVL 12.5 10 6 – tss ⋅⋅ > C VDD 810 4 1 D RST -------------- 1 – ⎝⎠ ⎛⎞ C OVL I DDch2 ⋅ V DDhyst --------------------------------------- ⋅⋅ ⋅ > |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |