4 / 22 page ![]() www.sensirion.com / D1 Version 1.0 – May 2025 4 / 22 2 Humidity and Temperature Sensor Specifications Every SHT41A-AWSB is individually tested and calibrated and is identifiable by its unique serial number (see section 4.6 for details on the serial number). For the calibration, Sensirion uses transfer standards, which are subject to a scheduled calibration procedure. The calibration of the reference, used for the calibration of the transfer standards, is NIST traceable through an ISO/IEC 17025 accredited laboratory. 2.1 Relative Humidity Parameter Conditions Value Units SHT41A RH accuracy typ. 2 %RH max. See Figure 2 - Repeatability1 high 0.08 %RH medium 0.15 %RH low 0.21 %RH Resolution2 - 0.01 %RH Hysteresis At 25°C, 50%RH 0.8 %RH Specified range3 extended4 0 to 100 %RH Response time5 t63% 4 s Long-term drift6 typ. <0.20 %RH/y Table 1. General relative humidity sensor specifications. Figure 2. SHT41A typical and maximal relative humidity accuracy at 25 °C. 1 The stated repeatability is 3 times the standard deviation (3σ) of multiple consecutive measurement values at constant conditions and is a measure for the noise on the physical sensor output. Different repeatability commands are listed in Table 7. 2 Resolution of A/D converter. 3 Specified range refers to the range for which the humidity or temperature sensor specification is guaranteed. 4 For details about recommended humidity and temperature operating range, please refer to section 2.4. 5 Time for achieving 63% of a humidity step function, measured at 25 °C and 1 m/s airflow. Humidity response time in the application depends on the design-in of the sensor. 6 Typical value for operation in normal RH/T operating range. Max. value is <0.5 %RH/y. Value may be higher in environments with vaporized solvents, out-gassing tapes, adhesives, packaging materials, etc. For more details, please refer to the document Handling Instruction for Humidity and Temperature Sensors [1]. ±0 ±2 ±4 ±6 ±8 0 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%RH) SHT41A typ SHT41A max RH (%RH) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |