| 数据搜索系统,热门电子元器件搜索 |
|
SHT41A-AWSB-R3 数据表(PDF) 5 Page - Sensirion AG Switzerland |
|
|
|||||||||||||||||||||||||||||
SHT41A-AWSB-R3 数据表(HTML) 5 Page - Sensirion AG Switzerland |
|
5 / 22 page ![]() www.sensirion.com / D1 Version 1.0 – May 2025 5 / 22 2.2 Relative Humidity Accuracy at the Extended Temperature Range The typical RH accuracy tolerances in the range of T = 0 °C … 80 °C are given in Figure 3. RH (%RH) SHT41A [typ. Delta %RH] 100 2 90 80 70 60 50 40 30 20 10 0 0 10 20 25 30 40 50 60 70 80 Temperature [°C] Figure 3. Typical RH accuracy tolerance over humidity and temperature for SHT41A. 2.3 Temperature Parameter Conditions Value Units SHT41A T Accuracy1 typ. 0.2 °C max. See Figure 4 - Repeatability1 high 0.04 °C medium 0.07 °C low 0.1 °C Resolution2 - 0.01 °C Specified range3 - –40 to +125 °C Response time7 t63% 2 s Long-term drift8 typ. <0.03 °C/y Table 2. General temperature sensor specifications. 7 Temperature response time depends on heat conductivity of sensor substrate and design-in of sensor in application. 8 Max. value is <0.04°C/y. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |