11 / 23 page ![]() www.sensirion.com / D1 Version 3.3 – November 2024 11 / 23 3.3.5 Set pressure The concentration measurement requires compensation of pressure. With the set pressure command, the sensor uses the input to compensate the concentration results. The pressure should be updated just before a new measurement is started. Pressure compensation is valid from 600 mbar to 1500 mbar. Command Command code (hex) Argument Description Set pressure 0x362F Absolute pressure: 16bit unsigned integer For pressure scaling, see section 3.5.4. When no value is written to the sensor after a soft reset, wake-up or power-up, a pressure of 1013mbar is assumed. The value written is used until a new value is written to the sensor. This command sequence needs to be closed off with a valid CRC byte for the 16-bit argument if the CRC is not disabled. When the CRC byte does not match the argument, the sensor will respond with a NACK. The sensor will omit the command and will use the previous value, or when no value was written, assume the default value of 1013mbar. 3.3.6 Measure gas concentration The duration of a gas concentration measurement is defined in section 2.4. When measurement data is available, it can be read out by sending an I2C read header and reading out the data from the sensor. If no measurement data is available yet, the sensor will respond with a NACK on the I2C read header. The gas model needs to be set once before the measurement command, see 3.3.2. Command Command code (hex) Consecutive read Description Measure gas concentration 0x3639 Byte1: Gas concentration 8msb Byte2: Gas concentration 8lsb Byte3: CRC Byte4: Temperature 8msb Byte5: Temperature 8lsb Byte6: CRC Byte7: Reserved 8msb Byte8: Reserved 8lsb Byte9: CRC The gas concentration is a 16-bit unsigned integer. The temperature and byte 7 and 8 do not need to be read out. The read sequence can be aborted after any byte by a NACK and a STOP condition. In case the ‘Set temperature command’ has been used prior to the measurement command, the temperature value given out by the STC31-C will be that one of the ‘Set temperature command’. When the ‘Set temperature command’ has not been used, the internal temperature value can be read out. During product development it is recommended to compare the internal temperature value of the STC31-C and the temperature value of the SHT4x, to check whether both sensors are properly thermally coupled. The values must be within 0.7°C at room temperature. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |