| 数据搜索系统,热门电子元器件搜索 |
|
JAE 数据表(PDF) 10 Page - Sensata Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
JAE 数据表(HTML) 10 Page - Sensata Technologies, Inc. |
|
10 / 14 page ![]() Page 10 sensata.com Copyright © 2025 Sensata Technologies, Inc. Type JLE: UL Listed JLM: UL Listed Mid Trip Construction JRE: UL Recognized JREP: UL Recognized above 250 amps JRM :UL Recognized Mid Trip Construction JRMP: UL Recognized Mid Trip Construction above 250 amps JTE: UL Listed Telecom Specication JTEP: UL Listed Telecom Specication above 250 amps JTM: UL Listed Telecom Specication Mid Trip Construction JTMP: UL Listed Telecom Specication Mid Trip Construction above 250 amps JAE: Non Agency JAEP: Non Agency above 250 amps JAM: Non Agency Mid Trip Construction JAMP: Non Agency Mid Trip Construction above 250 amps Poles -1*: Single pole -2: Two poles -3: Three poles -4: Four poles -5: Five poles -6: Six poles *Single pole unit above 250 Amps are supplied as parallel milti-pole assemblies. The second decision must indicate the physical number of poles. Internal Conguration -0: Switch only -1: Series -3: Shunt construction*** -4: Relay construction*** -REC4: Auxiliary switch* (STD) .110 quick connect -REG4: Auxiliary switch* .110 quick connect** -REC5: Auxiliary switch* (STD) .187 quick connect -RLS4: Alarm switch* (STD) .110 quick connect -RLS5: Alarm switch* .187 quick connect -DAA4: Dual auxiliary & alarm switch* (STD) .110 quick connect -DAA5: Dual auxiliary & alarm switch* .187 quick connect * Auxiliary switch located in the left hand pole when viewed from the terminal end. All meter shunt and parallel pole builds that require an auxiliary switch will automatically get a XXX4 type switch. To connect to the switch terminals which are brought through the cover use a Molex 02-09-1104 or an Amp 770146-1 crimp terminal. ** Gold Contacts *** Shunt and Relay construction not available above 250 Amps and not available in UL Listed Breakers Frequency & Delay Standard 50: DC instant trip 51: DC short delay Option: 51F 52: DC med. delay Option: 52F 53: DC long delay Option: 53F 60: 50/60Hz instant trip 61: 50/60Hz short delay Option: 61F 62: 50/60Hz med. delay Option: 62F 63: 50/60Hz long delay Option: 63F SW: Switch only An F after any delay denotes high pulse tolerance construction JLM - 1 - 1REC4 - 51 - 1 - F1 - 250 - A - V ORDERING OPTIONS The ordering code for JAE/JRE/JLE F-Frame Circuit Protectors may be determined by following the steps in the decision tables shown here. The coding given permits a self-assigning part number for standard configurations. Factory part numbers are assigned to units with mixed ratings, combinations of styles or construction not listed in the Third Decision Table, etc. With these, it is suggested that order entry be by description and/or drawings, and a part number will be established. Additionally, it is standard policy to establish a factory-assigned part number whenever a descriptive drawing exists to ensure cross reference, traceability and manufacturing control. For example, the following is the code for a single pole breaker series trip, with mid-trip handle indication, auxiliary switch, short delay, 65 volts DC maximum voltage rating with 3/8-16 captive nuts in a current rating of 250 amperes and metric inserts. To determine the ordering number of your particular JAE/JRE/JLE unit, simply follow the steps shown. You may use this number to place an order or as a reference for further questions you may have. Example: JLM-1-IREC4-51-1-F1-250-A-V |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |