| 数据搜索系统,热门电子元器件搜索 |
|
JAE 数据表(PDF) 12 Page - Sensata Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
JAE 数据表(HTML) 12 Page - Sensata Technologies, Inc. |
|
12 / 14 page ![]() Page 12 sensata.com Copyright © 2025 Sensata Technologies, Inc. AGENCY APPROVALS & CERTIFICATIONS - UL 489 Listed - UL 489A Listed - CSA Certified - CUL/CUR Certified - TUV Certified - CCC Certified - AS 60947.2-2005 (equivalent to IEC 60947-2:2006+A1) Single-pole ratings: UL489, 250 amps max at 160 Vdc, 10,000 amp interrupting capacity and 250 amps max at 65 Vdc, 65,000 amp interrupting capacity. Multi-pole ratings: UL 489A, 800 amps max at 160 Vdc, 10,000 amp interrupting capacity and 1,200 amps max at 65 Vdc, 65,000 amp interrupting capacity. ISO-9001 Certified General notes for Agency Approvals All supplementary protectors are of the overcurrent (OC) type The family of protectors has been evaluated for end use application for use group (UG) A The terminals (FW) – Terminals are coded as follows: 0 – Suitable for factory wiring only 1 – Line terminals evaluated for field wiring 2 – Load terminals evaluated for field wiring 3 – Line and load terminals evaluated for field wiring The maximum voltage ratings for which the protectors have been tested are shown in the chart The current is the amperage range that the protectors have been tested The tripping current (TC) – Tripping current is coded as a percentage of the ampere rating 0 – Tripping current is less than 125% of ampere rating 1 – Tripping current is in the range of 125% to 135% of ampere rating 2 – Tripping current is more than 135% of ampere rating 3 – Tripping current is 135% and meets MCCB trip time requirements The overload rating (OL) - designates whether the protector has been tested for general use or motor starting applications. 0 – tested at 1.5 times amp rating for general use 1 – tested at 6 times AC rating or 10 times DC rating for motor starting The short circuit current rating (SC) – The short circuit rating in amperes following a letter and number designating the test conditions and any calibration following the short circuit test is defined below: C – Indicates short circuit test was conducted with series overcurrent protection U – Indicates short circuit test was conducted without series overcurrent protection 1 – Indicates a recalibration was not conducted as part of the short circuit testing 2 – Indicates a recalibration was performed as part of the short circuit testing 3 – Indicates recalibration was performed along with the dielectric and voltage withstand for “Suitable for Further Use” rating |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |