| 数据搜索系统,热门电子元器件搜索 |
|
TZ4ST-R2R 数据表(PDF) 16 Page - Autonics Corporation |
|
|
|||||||||||||||||||||||||||||
TZ4ST-R2R 数据表(HTML) 16 Page - Autonics Corporation |
|
16 / 16 page ![]() H-87 (A) Photo electric sensor (B) Fiber optic sensor (C) Door/Area sensor (D) Proximity sensor (E) Pressure sensor (F) Rotary encoder (G) Connector/ Socket (H) Temp. controller (I) SSR/ Power controller (J) Counter (K) Timer (L) Panel meter (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller (P) Switching mode power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device (T) Software (U) Other Dual PID Auto Tuning Control ● Write of setting value In case setting value is -100 A C K S T X 0 1 W D S 0 Symbol 103 102 101 100 E T X F S C A C K S T X 0 1 W D S 0 - 0 1 0 0 E T X B C C 06 02 30 31 57 44 53 30 2D 30 31 30 30 03 B C C ● Others: In case of no response of ACK ① When the address is not the same after receiving STX. ② When receiving buffer overflow is occurred. ③ When the baud rate or others communication setting value are not the same. ● When there are no ACK response ① Check the status of lines ② Check the communication condition(Setting value) ③ When assuming the problem is due to noise, try to operate communication 3 times more until recovery. ④ When occurred communication failure frequently, please adjust the communicating speed. Proper usage Simple "error" diagnosis Caution for using ● When the load (Heater etc) is not operated Please check operation of the OUT lamp located in front panel of the unit. If the OUT lamp does not operate, please check the parameter of all programmed mode. If lamp is operating, please check the output(Relay, SSR drive voltage) after separating output line from the unit. But, the out lamp is not operated for DC4-20mA ● When it displays OPEN during operation This is a warning that external sensor is open. Please turn off the power and check the wire state of the sensor. If sensor is not open disconnect sensor line from the unit and short the input +, - terminal. Turn on the power of the unit and check the controller displays room temperature. If this unit cannot display room temperature, this unit is broken. Please remove this unit and contact our service center. (When the input mode is thermocouple, it is available to display room temperature.) ● In case of indicating ERR0 in display This Error message is indicated in case of damaging inner chip program data by outer strong noise. In this case, please send the unit to our after service center after removing the unit from system. Noise protection is designed in this unit, but it does not stand up strong noise continuously. If bigger noise than specified(Max. 2kV) flows in the unit, it can be damaged. ● Please use the terminal(M3.5, Max. 7.2mm) when connecting the AC power source. ● Please use separated line from high voltage line or power line in order to avoid inductive noise. ● Please install power switch or circuit-breaker in order to cut power supply off. ● The switch or circuit-breaker should be installed near by users. ● This unit is designed for temperature controlling only. Do not apply this unit as a voltage meter or a current meter. ● Be sure to use compensating wire when extending wire from controller to thermocouple, otherwise a temperature deviation will occur at the point where wires are connected to each other. ● In case of using RTD sensor, 3-wire type must be used. If you need to extend the line, 3-wires must be used with the same thickness as the line. It might cause temperature difference if the resistance of line is different. ● In case of making power line and input signal line close, line filter for noise protection should be installed at power line and input signal line should be shielded. ● Keep away from the high frequency instruments.(High frequency welding machine & sewing machine, big capacitive SCR controller) ● If you want to change the input sensor, reset switches (SW1, SW2) according to each input specification after power off. Turn on power and then set sensor mode by front keys at second flow chart. ● This SSR and current of this controller are insulate from internal power. ● Do not connect power line to sensor connecting part. The inner circuit may be damaged. ● Installation environment It shall be used indoor. Altitude Max. 2000m. Pollution Degree 2 Installation Category Ⅱ. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |