11 / 16 page ![]() H-82 TZN/TZ Series (tun 1 mode) Auto tuning time Time(t) SV ℃ (tun 2 mode) Auto tuning time 70% of SV Time(t) SV ℃ Functions Auto tuning [ AtT] Sensor Break Alarm [ SBA] Sub output [ EU-1, EU-2] Error Loop Break Alarm [ LBA] PID auto tuning function automatically measures the thermal characteristics and response of the control system and then executes its value under high response & stability after calculating the time constant of PID required to control optimum temperature. ● Execute the auto tuning function at initial time after connecting the controller & the sensor. ● Execution of auto tuning is started when pressing AT key for 3 sec. or more. ● When the auto tuning is started, AT lamp will flash, and when the lamp is OFF, this operation will stop. ● While the auto tuning function is executing, it is stopped by pressing AT key for 5sec. or more. ● When the power turns off or the stop signal is applied while auto tuning function is executing, time constant of PID is not changed and it remembers the value before power turns off. ● Time constant of PID selected by auto tuning function can be changed in parameter 1 group. ● It has two kinds of auto tuning mode auto tuning operation is executed at setting value(SV) in TUN1 mode which is factory default. Auto tuning operation in TUN2 mode is executed in 70% of setting value(SV). Mode change is available in AtT of the parameter 2 group. ● Execute the auto tuning function again periodically, because the thermal characteristics for the control object can be changed when the controller is used continuously for a long time. Sub output can execute as main control output and sub function as well. There is one sub output in this unit. ● This sub output is relay "1a" contact output. ● 1 mode can be selected among 7 kinds of alarm mode or LBA operated when the heater line is cut, SBA operated when the sensor line is cut. ● The Sub output can be latched ON or automatically reset depending on the alarm option mode selected. ● When the sensor line or the heater line is cut, SBA or LBA output turns on. This "Output on" status must be reset by turning the power off. This function causes the sub output to turn on when the sensor line is cut or open. It is easier to check that whether the sensor line is cut or not through buzzer or etc by exterior sub output (relay contact). ● For using SBA function, set SBA at EU-1 or EU-2 in parameter 2 group and SBA output operates as EV1 OUT or EV2 OUT contact. LBA function is to diagnose an abnormal temperature of the control system. If the temperature of the control system is not changed within ±2 ℃ during setting time of LBA, the LBA output will be ON. Ex) When setting value(SV) is 300 ℃, process value(PV) is 50 ℃, this unit controls 100%. In this time if there is no change of system temperature, it recognizes Heater is cut off then LBA output will be ON. ● LBA output can be selected at EV1 of the parameter 2 group. ● If LBA output is not selected at event output, it will not be displayed in parameter 1 group. ● Set range of LBA: 1 to 999 sec. ● If thermal response of the control system is slow, LBA value should be set to a high value. ● LBA output operates when the manipulated value of the controller is 0% and 100%.In case the LBA output is ON, please check the following; ① Short-circuit or cutting of the temp. sensor. ② Abnormal condition of the equipment (magnet, sub-relay, etc.) ③ Abnormal condition of the load(heater, cooler) ④ Wrong-wiring or cutting of the other cables. ● Once SBA is ON due to broken sensor, it will not reset, although sensor is connected. In this case, turn off the power then turn on again. If error is occurred while the controller is operating,it will be displayed as follow. ● LLLL is flashing when measured input temperature is lower than input range of the sensor. ● HHHH is flashing when measured input temperature is higher than input range of the sensor. ● OPEN is flashing when the input sensor is not connected or its wire is cut. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |